Skip to main content
Schneider Electric MGP0633X — Miniature Circuit Breakers (MCB)

Schneider MGP0633X PowerPacT 4 MCCB, 63A 3P 36kA, Obsolete

MPNMGP0633X
Obsolete

Schneider Electric PowerPacT 4, MGP0633X, Molded Case Circuit Breaker, 3P, 63A, 415 V AC, 36 kA Icu, TM-D trip unit, LI protection, toggle control, panel-mounted.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0633X — Identification
ParameterValue
Product range (series)PowerPacT 4
Product/component typeCircuit breaker
Device applicationDistribution
MGP0633X — Ratings
ParameterValue
Rated current (In)63 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)415 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V
Rated impulse withstand voltage (Uimp)8 kV
Utilisation categoryCategory A
MGP0633X — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to BS EN 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In
Mechanical durability (cycles)50000 cycles
MGP0633X — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
MGP0633X — Approvals
ParameterValue
StandardsBS EN 60947-2
MGP0633X — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity36 kA Icu at 415 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity36 kA at 415 V AC 50/60 Hz
MGP0633X — Specifications
ParameterValue
Trip unit protection functionsLI

Product details

The Schneider Electric MGP0633X is a PowerPacT 4 molded case circuit breaker (MCCB) with three poles, rated 63 A at 40 °C, and a TM-D thermal-magnetic trip unit providing LI protection — L for overload (thermal, adjustable 44.1...63 A) and I for short-circuit (magnetic, fixed). It is designed for distribution in 250 A or 400/630 A panelboards, panel-mounted on a backplate, and can be installed horizontally or vertically. The toggle control type gives a clear visual indication of the contact position.

Breaking capacity and isolation — what the ratings mean

Rated 36 kA Icu (ultimate) and 36 kA Ics (service) at 415 V AC 50/60 Hz, this MCCB can safely interrupt a fault current up to 36 kA without needing replacement after a single high-fault event — the Ics equals Icu, so it remains functional after clearing a fault at its full rating.

Lifecycle status — obsolete, sourced to order

The MGP0633X is marked obsolete by the manufacturer.

Durability and mounting

Mechanical durability is rated at 50,000 cycles; electrical durability at 50,000 cycles at 440 V at In/2 and 30,000 cycles at 440 V at full In. The breaker occupies 3 module spaces on a 35 mm backplate, panel-mounted. No earth-leakage protection is integrated — that is handled separately downstream if required.

Frequently asked questions

Where can I buy MGP0633X and how do I get a price?

We source the MGP0633X to order against an RFQ through independent distribution channels. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is MGP0633X's listed standards compliance?

The MGP0633X is certified to BS EN 60947-2, the standard for low-voltage switchgear and controlgear — specifically for circuit breakers. It also carries suitability for isolation per that same standard.

What is the control type on MGP0633X?

The control type is toggle — a manual lever that provides a clear visual indication of the contact position (ON/OFF/TRIPPED).

MPN
MGP0633X