Schneider Electric MGP0634X — Miniature Circuit Breakers (MCB)

MGP0634X PowerPacT 4 MCCB, 63A 4P, 36kA Breaking Capacity

MPNMGP0634X
Obsolete

Schneider Electric PowerPacT 4, Molded Case Circuit Breaker, 4P, 63 A, 415 V AC, 36 kA Icu/Ics, TM-D thermal-magnetic trip unit, panel-mounted.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

MGP0634X — Identification
ParameterValue
Product range (series)PowerPacT 4
Product/component typeCircuit breaker
Device applicationDistribution
MGP0634X — Ratings
ParameterValue
Rated current (In)63 A at 40 °C
Poles configuration4P
Rated operational voltage (Ue)415 V AC 50/60 Hz
Rated insulation voltage (Ui)800 V
Rated impulse withstand voltage (Uimp)8 kV
Utilisation categoryCategory A
MGP0634X — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Earth-leakage protectionWithout
Suitability for isolationYes conforming to BS EN 60947-2
Electrical durability (cycles)50000 cycles at 440 V In/2 30000 cycles at 440 V In
Mechanical durability (cycles)50000 cycles
MGP0634X — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
MGP0634X — Approvals
ParameterValue
StandardsBS EN 60947-2
MGP0634X — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity36 kA Icu at 415 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity36 kA at 415 V AC 50/60 Hz
MGP0634X — Specifications
ParameterValue
Trip unit protection functionsLI

Product details

The MGP0634X is a Schneider Electric PowerPacT 4 molded case circuit breaker (MCCB) with 4 poles (3P + N), rated 63 A at 40 °C, for distribution in panelboards up to 630 A. It uses a thermal-magnetic TM-D trip unit providing LI protection — thermal overload (L) adjustable 44.1...63 A and fixed magnetic short-circuit (I). Rated operational voltage is 415 V AC 50/60 Hz with an insulation rating of 800 V and impulse withstand of 8 kV. It is panel-mounted, fits both horizontal and vertical orientations, and occupies 4 module spaces (35 mm per module). The toggle control type gives clear visual indication of the contact position.

For a BOM freeze or replacement project, the official successor within the PowerPacT range should be verified against your panelboard's mounting and busbar pattern. The MGP0634X is isolation-capable per BS EN 60947-2, so any substitute must carry the same isolation marking if the application requires it.

The breaker complies with BS EN 60947-2, the standard for low-voltage switchgear and controlgear — circuit breakers. It is suitability for isolation conforming to that standard, meaning it provides a visible break and meets the touch-safe gap requirements when open.

Frequently asked questions

Where can I buy MGP0634X and what is the lead time?

We source the MGP0634X to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for the latest position.

What are the key ratings of MGP0634X?

Rated 63 A at 40 °C, 4-pole, 415 V AC 50/60 Hz, with 36 kA Icu and Ics short-circuit breaking capacity at 415 V. The TM-D trip unit provides adjustable thermal overload (44.1...63 A) and fixed magnetic short-circuit protection.

What standard does MGP0634X comply with?

It complies with BS EN 60947-2 and is suitability for isolation per that standard.