Skip to main content
Schneider Electric RE17RLMU

Schneider Electric RE17RLMU

MPNRE17RLMU
Active

Timing Relay, Flasher, 8A, 0.1 Sec - 10 Hours, 24 - 240V AC/DC|Timing Relay, Asymmetrical Flasher, Starting Pulse Off, Starting Pulse On, 8 Amp, 0.1 Second - 10 Hours Range, 24 - 240 Volt AC, 24 Volt DC

$27.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

RE17RLMU key specifications
ParameterValue
Control typeSelector switch front panel
Time delay typeAsymmetrical flashing
Range of productHarmony Timer Relays
Discrete output typeRelay
Product or component typeModular timing relay
Contacts type and composition1 C/O
Voltage drift+/- 0.2 %/V
Voltage range0.85...1.1 Us
Release of input voltage10 V
Maximum switching voltage250 V AC
Supply voltage24...240 V AC 50/60 Hz 24 V DC
[Uimp] rated impulse withstand voltage5 kV 1.2/50 µs

All specifications

RE17RLMU additional specifications
ParameterValue
Breaking capacity2000 VA
Nominal output current8 A
Maximum switching current8 A AC/DC
Minimum switching current10 mA 5 V DC
Power on delay100 ms
Power consumption in0...32 VA 240 V AC
Maximum power consumption in0.6 W 24 V DC
Supply frequency50...60 Hz +/- 5 %
Operating frequency10 Hz
IP degree of protectionIP20 IEC 60529 terminal block) IP40 IEC 60529 housing) IP50 IEC 60529 front panel)
Mounting support35 mm DIN rail conforming to IEC 60715
Mounting positionAny position in relation to normal vertical mounting plane
Connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end
Shock resistance15 gn 11 ms IEC 60068-2-27
Relative humidity93 % without condensation IEC 60068-2-30
Vibration resistance20 m/s² (f= 10...150 Hz) conforming to IEC 60068-2-6
Depth2.8 in (72 mm)
Width0.7 in (17.5 mm)
Height3.5 in (90 mm)
Housing materialPolycarbonate
Contacts materialCadmium free
Control signal pulse width100 ms with load in parallel typical 30 ms typical
Electrical durability100000 cycles resistive 8 A 250 V AC
Mechanical durability10000000 cycles
Standards2006/95/EC IEC 61000-6-2 IEC 61000-6-4 2004/108/EC IEC 61812-1 IEC 61000-6-3 IEC 61000-6-1
MarkingCE
CategoryUS10CP222370
Reset time120 ms on de-energisation typical
FunctionalityAsymmetrical flashing timer
On-load factor100 %
Repeat accuracy+/- 0.5 % IEC 61812-1
Local signallingLED indicator on steady: relay energised, no timing in progress LED indicator 80 % ON and 20 % OFF flashing: timing in progress
Time delay range1...10 h 1...10 s 0.1...1 s 6...60 min 1...10 min 10...100 h 6...60 s
Creepage distance4 kV/3 IEC 60664-1
Device short nameRE17R
Temperature drift+/- 0.05 %/°C
Tightening torque5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1
Compatibility codeRE17
Function availableL- Asymmetrical flashing relay (starting pulse-off)-1 C/O Li- Asymmetrical flashing relay (starting pulse-on)-1 C/O
Dielectric strength2.5 kV 1 mA/1 minute 50 Hz IEC 61812-1
Number of functions2
Insulation resistance100 MOhm 500 V DC IEC 60664-1
Immunity to microbreaks20 ms
Safety reliability dataMTTFd = 296.8 years B10d = 270000
Electromagnetic compatibilityElectrostatic discharge immunity test 6 kV in contact) level 3 IEC 61000-4-2 Electrostatic discharge immunity test 8 kV in air) level 3 IEC 61000-4-2 Susceptibility to electromagnetic fields 10 V/m 80 MHz to 1 GHz) level 3 IEC 61000-4-3 Electrical fast transient/burst immunity test 1 kV capacitive connecting clip) level 3 IEC 61000-4-4 Electrical fast transient/burst immunity test 2 kV direct) level 3 IEC 61000-4-4 1.2/50 µs shock waves immunity test 1 kV differential mode) level 3 IEC 61000-4-5 1.2/50 µs shock waves immunity test 2 kV common mode) level 3 IEC 61000-4-5 Conducted RF disturbances 10 V 0.15...80 MHz) level 3 IEC 61000-4-6 Voltage dips and interruptions immunity test 0 % 1 cycle) IEC 61000-4-11 Voltage dips and interruptions immunity test 70 % 25/30 cycles) IEC 61000-4-11 Conducted and radiated emissionsclass B EN 55022
Setting accuracy of time delay+/- 10 % of full scale 25 °C IEC 61812-1
Ambient air temperature for storage-22...140 °F (-30...60 °C)
Ambient air temperature for operation-4...140 °F (-20...60 °C)
MPN