Skip to main content
Schneider Electric REG48PUN2LRHU

Schneider Electric REG48PUN2LRHU

MPNREG48PUN2LRHU
Obsolete

temperature control relay REG - 48 x 48 mm - 100..240 V AC - 1 relay NO

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

REG48PUN2LRHU key specifications
ParameterValue
TypeTemperature control relays
Output signalSolid state 24 V DC 20 mA Relay 220 V AC 3 A
Display type7 segments LCD
Range of productZelio Control
Analogue input typeTemperature probe Pt 100 Thermocouple thermocouple J, K, R, B, S, T, E, N, PLII Current 4...20 mA Voltage 1...5 V Current 0...20 mA Voltage 0...0.1 V Voltage 0...10 V Voltage 0...5 V Voltage 2...10 V
Product or component typeModular measurement and control relays
Supply voltage limits85...264 V
Supply voltage100...240 V AC
Power consumption in12 VA 100...240 V AC
I/O channels1 solid state 1 relay NO
IP degree of protectionIP66 IEC 60529 front face) IP20 rear)
NEMA degree of protectionNEMA 4X front face

All specifications

REG48PUN2LRHU additional specifications
ParameterValue
Physical interfaceRS485 non isolated
Communication port protocolModbus
Mounting supportPanel
Shock resistance5 gn IEC 60068-2-27
Storage altitude0...9842.5 ft (0...3000 m)
Relative humidity90 % without condensation
Operating altitude6561.68 ft (2000 m)
Vibration resistance1 gn (f= 10...70 Hz) conforming to IEC 60068-2-6
Outer dimension1/16 DIN 48 x 48 mm
StandardsEN 61010-1 EN 61326-1 CSA C22.2 No 24-93
MarkingCE
Category22380-RELAYS-MEASUREMENT (RM17-RM35)
Relay nameREG
Alarm output2 C/O
Exchange modeHalf duplex
Display digits4
Method of accessSlave
Sampling duration200 ms
Transmission rate9600, 19200 kbit/s
Function availableSoft start Manual operation Auto tuning PID Hysteresis on-off Fuzzy logic Ramp 16 steps
Operating positionAny position
Transmission frameRTU
Signalling functionSetpoint value indicator (SV) LED Green Process output 1 active (C1) LED Red Alarm output 1 active (D01) LED Green Alarm output 2 active (D02) LED Green Process output 2 active (C2) LED Red Process value indicator (PV) LED Red Process value LCD display Setpoint value LCD display
Measurement accuracy0.3 % full scale
Product specific applicationHVAC Heating and cooling Packaging Industrial machines
Ambient air temperature for storage-4...140 °F (-20...60 °C)
Ambient air temperature for operation14...122 °F (-10...50 °C)
MPN
REG48PUN2LRHU