Schneider Electric REG96PUN1LHU
MPNREG96PUN1LHU
Obsolete
temperature control relay REG - 96 x 48 mm - 100..240 V AC - 1 solid state relay
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Type | Temperature control relays |
| Output signal | Solid state 24 V DC 20 mA |
| Display type | 7 segments LCD |
| Range of product | Zelio Control |
| Analogue input type | Temperature probe Pt 100 Thermocouple thermocouple J, K, R, B, S, T, E, N, PLII Current 4...20 mA Voltage 1...5 V Current 0...20 mA Voltage 0...0.1 V Voltage 0...10 V Voltage 0...5 V Voltage 2...10 V |
| Product or component type | Modular measurement and control relays |
| Supply voltage limits | 85...264 V |
| Supply voltage | 100...240 V AC |
| Power consumption in | 12 VA 100...240 V AC |
| I/O channels | 1 solid state |
| IP degree of protection | IP66 IEC 60529 front face) IP20 rear) |
| NEMA degree of protection | NEMA 4X front face |
All specifications
| Parameter | Value |
|---|---|
| Physical interface | RS485 non isolated |
| Communication port protocol | Modbus |
| Mounting support | Panel |
| Shock resistance | 5 gn IEC 60068-2-27 |
| Storage altitude | 0...9842.5 ft (0...3000 m) |
| Relative humidity | 90 % without condensation |
| Operating altitude | 6561.68 ft (2000 m) |
| Vibration resistance | 1 gn (f= 10...70 Hz) conforming to IEC 60068-2-6 |
| Outer dimension | 96 x 48 mm 1/8 DIN |
| Standards | EN 61010-1 CSA C22.2 No 24-93 EN 61326-1 |
| Marking | CE |
| Category | 22380-RELAYS-MEASUREMENT (RM17-RM35) |
| Relay name | REG |
| Alarm output | 3 C/O |
| Exchange mode | Half duplex |
| Display digits | 4 |
| Method of access | Slave |
| Sampling duration | 200 ms |
| Transmission rate | 9600, 19200 kbit/s |
| Function available | Auto tuning PID Fuzzy logic Ramp 16 steps Hysteresis on-off Soft start Manual operation |
| Operating position | Any position |
| Transmission frame | RTU |
| Signalling function | Setpoint value indicator (SV) LED Green Process output 1 active (C1) LED Red Process output 2 active (C2) LED Red Process value indicator (PV) LED Red Process value LCD display Setpoint value LCD display Alarm output 1 active (D01) LED Alarm output 2 active (D02) LED Alarm output 3 active (D03) LED |
| Measurement accuracy | 0.3 % full scale |
| Product specific application | Industrial machines HVAC Heating or cooling Packaging |
| Ambient air temperature for storage | -4...140 °F (-20...60 °C) |
| Ambient air temperature for operation | 14...122 °F (-10...50 °C) |
MPN
REG96PUN1LHU