Skip to main content
Schneider Electric REL52128

Schneider Electric REL52128

MPNREL52128
Active

Square D REL52128 230V Prot Realy|Square D REL52128 230V Prot Realy

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

REL52128 key specifications
ParameterValue
Display typeLCD 128 x 128 pixels with single line diagram LCD 128 x 128 pixels with ANSI symbols
Range of productPowerLogic P3
Product or component typeProtection relay
Switchgear diagnosis typeCT/VT supervision Trip circuit supervision TCS
Climatic withstandExposure to dry heat Bd EN/IEC 60068-2-2 Exposure to cold Ad EN/IEC 60068-2-1 Exposure to damp heat in service Db EN/IEC 60068-2-30 Exposure to damp heat in service Cab EN/IEC 60068-2-78
Power supply48...230 V AC/DC
IP degree of protectionIP54 front IEC 60529
Communication portsFront USB port 1 Rear RJ45 1 Rear RS485 1
Communication protocolsIEC 61850 ed. 1 IEC 61850 ed. 2 IEC 60870-5-101 DNP3 TCP Modbus TCP EtherNet/IP IEC 60870-5-103 DNP3 Modbus RTU DeviceNet SPAbus
Time synchronisation protocolSNTP
Mounting modeFlush mounting
Device mountingFlush

All specifications

REL52128 additional specifications
ParameterValue
Mounting case size30TE
Connections - terminalsScrew removable (digital input/output) Ring lugs fixed (current transformer) Pin removable (voltage transformer)
Relative humidity0...95 %, without condensation
Maximum operating altitude6561.68 ft (2000 m)
Depth9.06 in (230 mm)
Width10.6 in (270 mm)
Height6.9 in (176 mm)
CategoryUS1PL1S11405
Web serverEmbedded HTTP server
CybersecurityPassword protection Port hardening
Number of key2 customizable
Software nameESetup Easergy Pro virtual simulation test Easergy SmartApp
Local signalling2 LEDs 16 LEDs programmable
Logs and recordsEvent recording Disturbance recording Tripping context
Measuring inputs3 1/5 A CT phase current 1 5/1 A CT residual current 1 1/0.2 A CT residual current 4 100 V/110 V VT voltage
Control functionsSwitchgear control and monitoring Programmable switchgear interlocking Local control on single-line diagram Local control with I/O keys Local/remote control 2 function keys Mobile application with Easergy SmartApp Web-server Programmable logic
Product referenceP3F30-CBGAD-DA1FA-BBAAB
Relay applicationFeeder
Operating threshold110 V AC/DC
Arc flash protectionYes
Monitoring functionsTrip circuit supervision 74 Circuit breaker monitoring Relay self-monitoring
Protection functionsFault locator 21FL Synchro-check 25 Undervoltage 27 Directional active underpower 32 Broken conductor 46BC Thermal overload protection 49 Earth fault overcurrent 50N/51N Phase overcurrent 50/51 Breaker failure 50BF Switch ON to fault (SOTF) Capacitor bank unbalance 51C Voltage-restrained overcurrent 51V Capacitor overvoltage 59C Overvoltage 59 Earth fault overvoltage 59N Directional phase overcurrent 67 Directional earth fault 67N Transient earth fault 67NI Magnetising inrush detection 68F2 H5 detection 68H5 Recloser 79 Underfrequency 81/81N Rate of change of frequency 81R Lockout relay 86 Programmable stages 99 8 Programmable curve Cold load pick-up CT supervision 60 VT supervision 60FL
Protective treatmentConformal coating
Measurement functionsCurrent 3-phase Current zero sequence Current positive sequence Current negative sequence Current ratio of negative and positive Voltage phase to earth Voltage phase to phase Voltage zero sequence Voltage positive sequence Voltage negative sequence Voltage ratio of negative and positive Short circuit fault reactance Fault location current Earth fault reactance Frequency Active power RMS active power Reactive power RMS reactive power Apparent power RMS apparent power Active energy Reactive energy Cos φ Tan φ Power angle Power factor Voltage phasor diagram view Current phasor diagram view Current 2nd, 15th harmonics with THD Voltage 2nd, 15th harmonics with THD Condition monitoring CB wear Voltage interruption
Mechanical robustnessVibrations class II) IEC 60255-21-1 VibrationsFc IEC 60068-2-6 Shocks class II) IEC 60255-21-2 ShocksEa IEC 60068-2-27 Seismic tests method A class II) IEC 60255-21-3
Number of setting groups4
Number of analogue inputs0
Number of analogue outputs0
Electromagnetic compatibilityEmission tests IEC/EN 60255-26 ed. 3 Emission tests class A CISPR 11 Emission tests class A CISPR 22 EMC immunity IEC/EN 60255-26 ed. 3 EMC immunity EN/IEC 61000-4-18 EMC immunity IEC 60255-22-1 EMC immunity level 4 EN/IEC 61000-4-2 EMC immunity IEC 60255-22-2 EMC immunity level 3 EN/IEC 61000-4-3 EMC immunity IEC 60255-22-3 EMC immunity level 4 EN/IEC 61000-4-4 EMC immunity IEC 60255-22-4 EMC immunity level 3 EN/IEC 61000-4-5 EMC immunity IEC 60255-22-5 EMC immunity level 3 EN/IEC 61000-4-6 EMC immunity IEC 60255-22-6 EMC immunity EN/IEC 61000-4-8 EMC immunity level 5 EN/IEC 61000-4-9 EMC immunity EN/IEC 61000-4-29 EMC immunity EN/IEC 61000-4-11 EMC immunity EN/IEC 61000-4-17 EMC immunity IEC 60255-27 EMC immunity class III IEC 60255-5 EMC immunity EN/IEC 60255-1
Number of digital inputs6
Number of digital outputs10 DO 1 watchdog
Controllable switchgear devices3 controlled + 5 displayed
Ambient air temperature for operation-40...149 °F (-40...65 °C)
MPN
REL52128