Schneider Electric REL79207
MPNREL79207
Active
Stand-alone merging unit, PowerLogic P7, application Standard flexibility, 10CT, 8VT, 24BI, 20BO, 48-125V, ethernet RJ45
$7,213.79Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Display type | Without Display |
| Range of product | PowerLogic P7 |
| Type of measurement | Earth fault current external measurement |
| Product or component type | Stand alone merging unit |
| Switchgear diagnosis type | CT/VT supervision 60 DC battery voltage monitoring Cumulative breaking current Number of operations Trip circuit supervision 74 |
| Climatic withstand | Exposure to cold Ae IEC 60068-2-1 Exposure to dry heat Be IEC 60068-2-2 Exposure to damp heat in service Cab IEC 60068-2-78 Temperature variation Nb IEC 60068-2-14 Exposure to damp heat not in service Cab IEC 60068-2-30 Salt mist Kb/1 IEC 60068-2-52 Influence of corrosion/gas test 2 Ke IEC 60068-2-60 Influence of corrosion/gas test 4 Ke IEC 60068-2-60 |
| Power supply | 48...125 V DC |
| Input power interruption | 50 ms 100 ms |
| Maximum power consumption in | 24 W typical |
| IK degree of protection | IK07 conforming to IEC 62262 |
| IP degree of protection | IP54 front IEC 60529 IP30 case IEC 60529 IP20 rear IEC 60529 |
| Communication ports | 1 CAN port 1 Ethernet TCP/IP 2 SFP ports 1 USB port 1 COM serial link 1 PoE port |
All specifications
| Parameter | Value |
|---|---|
| Communication protocols | Modbus serial and TCP DNP3 serial and TCP IEC 61850 Ed 2.1 IEC 61869-9 IEC 61850-9-2 LE |
| Time synchronisation protocol | IRIG-B SNTP PTP IEEE 1588 |
| Redundancy communication port protocol | HSR PRP RSTP Failover |
| Mounting mode | Panel mounting Rack-mounted with kit Wall mounted |
| Device mounting | Panel mounting |
| Mounting support | 19" rack |
| Mounting case size | 40TE |
| Device connection | Connection to a PC RJ45 Extension port extension cable Ethernet port RJ45 Serial port RS485 cable SFP redundant Ethernet port fibre optic/RJ45 multi/single mode optional PoE port RJ45 |
| Connections - terminals | Screw type terminals (digital input/output) Ring terminal (current transformer) Pin terminal (voltage transformer) |
| Maximum operating altitude | 6561.68 ft (2000 m) |
| Depth | 11.02 in (280 mm) |
| Width | 8.07 in (205 mm) |
| Height | 7.09 in (180 mm) |
| Category | US1PL1S11407 |
| Cybersecurity | IEC 62443 SL2 LDAP RADIUS based user authentication Port hardening Role-based access control Secure boot Security log Syslog protocol support Firmware signature Client IP address filter Pre-login banner Security policy management |
| Software name | PowerLogic Engineering Suite |
| Data recording | Maintenance logs Event logs Sequence of event recording |
| Local signalling | 4 LEDs green/yellow device status |
| Logs and records | Operation log |
| Measuring inputs | 8 CT 1/5 A 2 CT 1 A 8 VT |
| Control functions | Switchgear control and monitoring Programmable switchgear interlocking Programmable logic Remote control |
| Product reference | P7 |
| Relay application | Merging unit application and bay control |
| Operating threshold | 48 V DC 110 V DC |
| Monitoring functions | Circuit breaker monitoring Switch monitoring Relay self-monitoring Event counters Watchdog |
| Protection functions | Directional phase overcurrent 67 Phase overcurrent 50/51 Overvoltage 59 Undervoltage 27 Temperature monitoring 38/49T CT supervision 60 VT supervision 60FL Programmable logic |
| Protective treatment | Conformal coating conforming to IEC 60068-2-52:Kb/1 Conformal coating conforming to IEC 60068-2-60:Ke |
| Mechanical robustness | Vibrations class 2) IEC 60255-21-1 Shocks class 2) IEC 60255-21-2 Shocks class 1) IEC 60255-21-2 Bumps class 1) IEC 60255-21-2 Seismic tests class 2) IEC 60255-21-3 |
| Electromagnetic compatibility | Electromagnetic immunity class A CISPR 11 Electromagnetic immunity class A CISPR 32 Electromagnetic immunity level 3 IEC 6100-4-3 Electromagnetic immunity class A IEC 60255-26 Radiated radio-frequency electromagnetic field immunity test level 4 ANSI C37.90.2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 60255-26 Electrostatic discharge level 4 IEC 6100-4-2 Electrostatic discharge level 4 ANSI C37.90.3 Electrostatic discharge level 4 IEC 60255-26 Immunity to magnetic fields level 5 IEC 61000-4-8 Immunity to magnetic fields level 5 IEC 60255-26 Immunity to magnetic fields level 5 IEC 61000-4-9 Fast transient bursts level 4 IEC 60255-26 Fast transient bursts level 4 IEC 61000-4-4 Damped oscillatory wave level 3 IEC 61000-4-18 Damped oscillatory wave level 4 ANSI C37.90.1 Damped oscillatory wave level 3 IEC 60255-26 Damped oscillatory wave level 3 IEC 61000-4-12 Conducted disturbance emission A IEC 61000-4-16 Surges level 4 IEC 61000-4-5 Surges level 4 IEC 60255-26 |
| Number of digital inputs | 24 |
| Number of digital outputs | 20 1 watchdog |
| Controllable switchgear devices | 12 controlled objects including 4 CBs |
| Ambient air temperature for storage | -40...185 °F (-40...85 °C) (96 h) |
| Ambient air temperature for operation | -40...158 °F (-40...70 °C) 96 h ) |
MPN