Stand-alone merging unit, PowerLogic P7, application Standard flexibility, 10CT, 8VT, 24BI, 20BO, 110-250V, ethernet RJ45

$7,213.79Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

REL79208 key specifications
ParameterValue
Display typeWithout Display
Range of productPowerLogic P7
Type of measurementEarth fault current external measurement
Product or component typeStand alone merging unit
Switchgear diagnosis typeCT/VT supervision 60 DC battery voltage monitoring Cumulative breaking current Number of operations Trip circuit supervision 74
Climatic withstandExposure to cold Ae IEC 60068-2-1 Exposure to dry heat Be IEC 60068-2-2 Exposure to damp heat in service Cab IEC 60068-2-78 Temperature variation Nb IEC 60068-2-14 Exposure to damp heat not in service Cab IEC 60068-2-30 Salt mist Kb/1 IEC 60068-2-52 Influence of corrosion/gas test 2 Ke IEC 60068-2-60 Influence of corrosion/gas test 4 Ke IEC 60068-2-60
Power supply110...250 V DC 110...250 V AC 50/60 Hz
Input power interruption100 ms 200 ms
Maximum power consumption in24 W typical
IK degree of protectionIK07 conforming to IEC 62262
IP degree of protectionIP54 front IEC 60529 IP30 case IEC 60529 IP20 rear IEC 60529
Communication ports1 CAN port 1 Ethernet TCP/IP 2 SFP ports 1 USB port 1 COM serial link 1 PoE port

All specifications

REL79208 additional specifications
ParameterValue
Communication protocolsModbus serial and TCP DNP3 serial and TCP IEC 61850 Ed 2.1 IEC 61869-9 IEC 61850-9-2 LE
Time synchronisation protocolIRIG-B SNTP PTP IEEE 1588
Redundancy communication port protocolHSR PRP RSTP Failover
Mounting modePanel mounting Rack-mounted with kit Wall mounted
Device mountingPanel mounting
Mounting support19" rack
Mounting case size40TE
Device connectionConnection to a PC RJ45 Extension port extension cable Ethernet port RJ45 Serial port RS485 cable SFP redundant Ethernet port fibre optic/RJ45 multi/single mode optional PoE port RJ45
Connections - terminalsScrew type terminals (digital input/output) Ring terminal (current transformer) Pin terminal (voltage transformer)
Maximum operating altitude6561.68 ft (2000 m)
Depth11.02 in (280 mm)
Width8.07 in (205 mm)
Height7.09 in (180 mm)
CategoryUS1PL1S11407
CybersecurityIEC 62443 SL2 LDAP RADIUS based user authentication Port hardening Role-based access control Secure boot Security log Syslog protocol support Firmware signature Client IP address filter Pre-login banner Security policy management
Software namePowerLogic Engineering Suite
Data recordingMaintenance logs Event logs Sequence of event recording
Local signalling4 LEDs green/yellow device status
Logs and recordsOperation log
Measuring inputs8 CT 1/5 A 2 CT 1 A 8 VT
Control functionsSwitchgear control and monitoring Programmable switchgear interlocking Programmable logic Remote control
Product referenceP7
Relay applicationMerging unit application and bay control
Operating threshold110 V DC 220 V DC
Monitoring functionsCircuit breaker monitoring Switch monitoring Relay self-monitoring Event counters Watchdog
Protection functionsDirectional phase overcurrent 67 Phase overcurrent 50/51 Overvoltage 59 Undervoltage 27 Temperature monitoring 38/49T CT supervision 60 VT supervision 60FL Programmable logic
Protective treatmentConformal coating conforming to IEC 60068-2-52:Kb/1 Conformal coating conforming to IEC 60068-2-60:Ke
Mechanical robustnessVibrations class 2) IEC 60255-21-1 Shocks class 2) IEC 60255-21-2 Shocks class 1) IEC 60255-21-2 Bumps class 1) IEC 60255-21-2 Seismic tests class 2) IEC 60255-21-3
Electromagnetic compatibilityElectromagnetic immunity class A CISPR 11 Electromagnetic immunity class A CISPR 32 Electromagnetic immunity level 3 IEC 6100-4-3 Electromagnetic immunity class A IEC 60255-26 Radiated radio-frequency electromagnetic field immunity test ANSI C37.90.2 Radiated radio-frequency electromagnetic field immunity test level 3 IEC 60255-26 Electrostatic discharge level 4 IEC 6100-4-2 Electrostatic discharge level 3 ANSI C37.90.3 Electrostatic discharge level 4 IEC 60255-26 Immunity to magnetic fields level 5 IEC 61000-4-8 Immunity to magnetic fields level 5 IEC 60255-26 Immunity to magnetic fields level 5 IEC 61000-4-9 Fast transient bursts level 4 IEC 60255-26 Fast transient bursts level 4 IEC 61000-4-4 Damped oscillatory wave level 3 IEC 61000-4-18 Damped oscillatory wave level 4 ANSI C37.90.1 Damped oscillatory wave level 3 IEC 60255-26 Damped oscillatory wave level 3 IEC 61000-4-12 Conducted disturbance emission A IEC 61000-4-16 Surges level 4 IEC 61000-4-5 Surges level 4 IEC 60255-26
Number of digital inputs24
Number of digital outputs20 1 watchdog
Controllable switchgear devices12 controlled objects including 4 CBs
Ambient air temperature for storage-40...185 °F (-40...85 °C) (96 h)
Ambient air temperature for operation-40...158 °F (-40...70 °C) 96 h )