RelayAux - flush mounting socket screw base for auxiliary relay connection

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

REL91359 key specifications
ParameterValue
Range of productRelayAux
Product or component typeSocket
[Uimp] rated impulse withstand voltage5 kV during 1.2/50 µs conforming to IEC 60255-5
IP degree of protectionIP20 conforming to IEC 60529
Device mountingFlush
Operating altitude< 2000 m
Vibration resistance1 gn (f = 58...150 Hz) conforming to IEC 60068-2-1 +/- 0.075 mm (f = 10...58 Hz) conforming to IEC 60068-2-1
Maximum relative humidity93 % at 40 °C
Depth124 mm
Width75 mm
Height80 mm
Contacts materialAgNi

All specifications

REL91359 additional specifications
ParameterValue
Directives72/23/EEC - low voltage directive 93/68/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility 92/31/EEC - electromagnetic compatibility
Fire resistance850 °C during 30 s
Dielectric strength2 kV 50 Hz 1 min conforming to IEC 60255-5
Mechanical robustnessShocks 11 ms (5 gn) conforming to IEC 60068-2-27 Bumps 16 ms (10 Gn) conforming to IEC 60068-2-29
Electromagnetic compatibilityConducted and radiated emissions criteria A conforming to EN 55022 Conducted and radiated emissions criteria B conforming to EN 55022 Electrostatic discharge - test level: 15 kV level 4 (air discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 4 (contact discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m, 80 MHz...1 GHz level 3 conforming to IEC 61000-4-3 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m, 80 MHz...1 GHz level 3 conforming to ENV 50204 Electrical fast transient/burst immunity test - test level: 4 kV, 5 kHz level 4 (1 min) conforming to IEC 61000-4-4 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Conducted RF disturbances - test level: 10 V, 0.15...80 MHz level 3 conforming to IEC 61000-4-6 Magnetic field at power frequency - test level: 100 A/m level 5 (continuous) conforming to IEC 61000-4-8 Magnetic field at power frequency - test level: 1000 A/m level 5 (2 s) conforming to IEC 61000-4-8 Damped oscillating waves - test level: 2.5 kV, 1 MHz level 3 (common mode) conforming to IEC 60255-22-1 Damped oscillating waves - test level: 1 kV, 1 MHz level 3 (differential mode) conforming to IEC 60255-22-1
Insulation resistance measurements> 100 MOhm at 500 V DC conforming to IEC 60255-5
Ambient air temperature for storage-25...70 °C
Ambient air temperature for operation-25...70 °C