Specifications

RM17JA12M7 key specifications
ParameterValue
TypeCurrent control relay
Control typeWithout test button
Time delay typeAdjustable 0.1...30 s, +/- 10 % of the full scale value Tt- time delay upon fault
Range of productHarmony Control Relays
Product or component typeCurrent control relay
Contacts type and composition1 C/O
Supply voltage limits198...264 V AC
Dielectric test voltage2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1
Maximum switching voltage250 V AC
Supply voltage220...240 V AC/DC 50/60 Hz, self-powered
Operating voltage tolerance- 10 % + 10 % Un
Voltage250 V conforming to IEC 60664-1

All specifications

RM17JA12M7 additional specifications
ParameterValue
Nominal output current5 A
Maximum switching current5 A AC/DC
Minimum switching current10 mA at 12 V AC
Maximum power consumption in1.5 W AC
Control circuit frequency50...60 Hz +/- 5 %
Utilisation categoryAC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-1 conforming to IEC 60947-4-1 AC-1 conforming to IEC 60947-4-1
IP degree of protectionIP20 (terminals) conforming to IEC 60529 IP30 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529
Mounting support35 mm symmetrical DIN rail conforming to IEC 60715
Connections - terminalsScrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.5...1 x 2.5 mm² (AWG 20...AWG 14) flexible with cable end Screw terminals, 2 x 0.5...2 x 1.5 mm² (AWG 20...AWG 16) flexible with cable end
Resistance across terminals0.005 Ohm at L - Li
Pollution degree3 conforming to IEC 60664-1
Shock resistance15 gn for 11 ms conforming to IEC 60255-21-1
Relative humidity93...97 % at 25...55 °C conforming to IEC 60068-2-30
Vibration resistance0.35 mm (f= 5...57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6...150 Hz) conforming to IEC 60255-21-1
Non-dissipating shock wave4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5
Depth72 mm
Width17.5 mm
Height90 mm
Product weight0.07 kg
Housing materialPolycarbonate
Electrical durability100000 cycles
Mechanical durability30000000 cycles
StandardsEN/IEC 60255-1 UL 508
InsulationBetween supply and measurement
Relay nameRM17JA
Reset time1500 ms time delay
Operating rate<= 360 operations/hour full load
Output contacts1 C/O
Local signallingLED (green) for power ON LED (yellow) for relay ON
Measurement range0.5...10 A current AC 50/60 Hz
Tightening torque5.3...8.8 lb.in 0.6...1 N.m
Operating positionAny position without derating
Immunity to microbreaks50 ms
Maximum measuring cycle100 ms measurement cycle as true rms value
Switching capacity in1250 VA
Switching threshold drift500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
Relay monitored parametersOvercurrent or undercurrent in window mode Overcurrent or undercurrent detection
Electromagnetic compatibilityEmission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Ambient air temperature for storage-40...70 °C
Ambient air temperature for operation-20...60 °C
Setting accuracy of the switching threshold+/- 10 % of the full scale
MPN