Skip to main content
Schneider Electric RM22TG20

Schneider Electric RM22TG20

MPNRM22TG20
Active

PHASE CTRL RELAY 208-480VAC IN 8A DPDT|PHASE CTRL RELAY 208-480VAC IN 8A DPDT

$31.75 – $94.57Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

RM22TG20 key specifications
ParameterValue
TypeControl relay
Control typeWith test button
Time delay typeWithout
Range of productHarmony Control Relays
Product or component type3-phase control relay
Contacts type and composition2 C/O
Supply voltage limits183...528 V AC
Dielectric test voltage2.5 kV AC 50 Hz, 1 min IEC 60255-27
Supply voltage frequency50...60 Hz +/- 10 %
Maximum switching voltage250 V AC
Supply voltageAC/DC
[Un] rated nominal voltage, self-powered

All specifications

RM22TG20 additional specifications
ParameterValue
Voltage detection threshold< 100 V AC
Maximum switching current8 A AC
Minimum switching current10 mA 5 V DC
Power consumption in15 VA 480 V AC 60 Hz
Run-up delay at power-up650 ms
Phases3 phase
Utilisation categoryAC-15 IEC 60947-5-1 DC-13 IEC 60947-5-1 AC-1 IEC 60947-4-1 DC-1 IEC 60947-4-1
IP degree of protectionIP20 IEC 60529 terminals) IP40 IEC 60529 housing) IP50 IEC 60529 front panel)
Mounting support35 mm DIN rail conforming to IEC 60715
Mounting positionAny position
Connections - terminalsScrew terminals, 2 x 0.5...2 x 2.5 mm² AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² AWG 24...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² AWG 24...AWG 14) flexible with cable end
Response time100 MOhm 500 V DC IEC 60255-27
Pollution degree3 IEC 60664-1 3 UL 508
Shock resistance15 gn 11 ms) not in operation IEC 60068-2-27 5 gn 11 ms) in operation IEC 60068-2-27
Relative humidity93...97 % 77...131 °F (25...55 °C) IEC 60068-2-30
Vibration resistance0.075 mm 10...58.1 Hz) not in operation IEC 60068-2-6 1 gn 10...58.1 Hz) not in operation IEC 60068-2-6 0.035 mm 58.1...150 Hz) in operation IEC 60068-2-6 0.5 gn 58.1...150 Hz) in operation IEC 60068-2-6
Width0.9 in (22.5 mm)
Housing materialSelf-extinguishing plastic
Contacts materialCadmium free
Electrical durability100000 cycles
Mechanical durability10000000 cycles
StandardsIEC 60255-1
CategoryUS10CP222380
Relay nameRM22TG
Reset time1500 ms at maximum voltage
Status LEDLED (Yellow) relay ON LED (Green) power ON
Output contacts2 C/O
Operating limits183...528 V AC
Measurement range208...480 V voltage AC
Tightening torque5.3...8.9 lbf.in (0.6...1 N.m) IEC 60947-1
Immunity to microbreaks10 ms
Safety reliability dataMTTFd = 924.6 years B10d = 850000
Switching capacity in2000 VA
Relay monitored parametersPhase sequence Phase failure detection (2 or more phase cut)
Electromagnetic compatibilityImmunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Immunity for industrial environments conforming to IEC 61000-6-2 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Emission standard for industrial environments conforming to IEC 61000-6-4 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation-4...122 °F (-20...50 °C) 60 Hz -4...140 °F (-20...60 °C) 50 Hz AC/DC
MPN
RM22TG20