Skip to main content
Schneider Electric RM4TA01

Schneider Electric RM4TA01

MPNRM4TA01
Obsolete

three-phase network control relay RM4-T - range 200..240 V

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

RM4TA01 key specifications
ParameterValue
TypeControl relay
Time delay typeFixed 0.5 s
Range of productHarmony Relay
Product or component typeIndustrial measurement and control relays
Contacts type and composition1 C/O
Switching voltage250 V AC
Dielectric test voltage2.5 kV
Maximum switching voltage440 V AC
Voltage500 V IEC
[Ie] rated operational current2 A 158 °F (70 °C) 24 V DC-13 IEC 60947-5-1/1991 2 A 158 °F (70 °C) 24 V DC-13 VDE 0660 3 A 158 °F (70 °C) 115 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 115 V AC-15 VDE 0660 3 A 158 °F (70 °C) 24 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 24 V AC-15 VDE 0660 3 A 158 °F (70 °C) 250 V AC-15 IEC 60947-5-1/1991 3 A 158 °F (70 °C) 250 V AC-15 VDE 0660 0.1 A 158 °F (70 °C) 250 V DC-13 IEC 60947-5-1/1991 0.1 A 158 °F (70 °C) 250 V DC-13 VDE 0660 0.3 A 158 °F (70 °C) 115 V DC-13 IEC 60947-5-1/1991 0.3 A 158 °F (70 °C) 115 V DC-13 VDE 0660
[Ith] conventional free air thermal current8 A
Delay at power up650 ms

All specifications

RM4TA01 additional specifications
ParameterValue
Supply frequency50/60 Hz +/- 5 %
Poles description3P
IP degree of protectionIP20 IEC 60529 terminals) IP50 IEC 60529 casing)
Number of cables2
Connections - terminalsScrew terminals, 2 x 1.5 mm²flexible with cable end Screw terminals, 2 x 2.5 mm²flexible without cable end
Terminals description ISO n°1(15-16-18)OC (L1-L2-L3)CO
Pollution degree3 IEC 60664-1
Shock resistance15 gn 11 ms IEC 60068-2-27
Relative humidity15...85 % 3K3 IEC 60721-3-3
Vibration resistance0.35 ms (f= 10...55 Hz) conforming to IEC 60068-2-6
Non-dissipating shock wave4.8 kV
Depth3.1 in (80 mm)
Width0.9 in (22.5 mm)
Height3.07 in (78 mm)
Contacts material90/10 silver nickel contacts
Mechanical durability30000000 cycles
StandardsIEC 60255-6
MarkingCE
Category22376-RELAYS-MEASUREMENT(RM4)
Directives73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility
Hysteresis50 % fixed asymmetry percentage
Relay nameRM4-T
9 mm pitches2.5
Output contacts1 C/O
Time delay drift<= 0.5 % within the measuring range
Tightening torque5.3...9.7 lbf.in (0.6...1.1 N.m)
Operating positionAny position without derating
Output relay stateTripped, fault present
Overvoltage categoryIII conforming to IEC 60664-1
Maximum measuring cycle80 ms
Switching capacity in10 mA 12 V
Switching threshold drift<= 0.5 % within the measuring range
Relay monitored parametersPhase sequence Phase failure detection Asymmetry
Product specific applicationFor 3-phase supply
Electromagnetic compatibilityElectrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Resistance to electrostatic discharge - test level: 6 kV (contact) conforming to IEC 61000-4-2 level 3 Resistance to electrostatic discharge - test level: 8 kV (air) conforming to IEC 61000-4-2 level 3
Resistance to fast transients2 kV IEC 61000-4-4 level 3
Time delay on de-energisation0.5 s
Disturbance radiated (conducted)CISPR 11 group 1 - class A CISPR 22 - class A
Setting accuracy of time delay10 P
Adjustment of asymmetry threshold5...15 %
Ambient air temperature for storage-40...185 °F (-40...85 °C)
Resistance to electromagnetic fields9.1 V/m (10 V/m) IEC 61000-4-3 level 3
Ambient air temperature for operation-4...149 °F (-20...65 °C)
Resistance to electrostatic discharge6 kV contact IEC 61000-4-2 level 3 8 kV air IEC 61000-4-2 level 3
Setting accuracy of the switching threshold+/-3 %
MPN
RM4TA01