Skip to main content
Schneider Electric RUMF33FD

Schneider Electric RUMF33FD

MPNRUMF33FD
Active

universal plug in relay, Harmony Electromechanical Relays, 10A, 3CO, with LED, flat (faston) terminals, 110V DC

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

RUMF33FD key specifications
ParameterValue
TypeUniversal relay
Series nameRUM series
Control typeWithout lockable test button
Range of productHarmony Electromechanical Relays
Product or component typePlug-in relay
Contacts type and composition3 C/O
Maximum switching voltage250 V IEC
Drop-out voltage threshold>= 0.1 Uc DC
Coil voltage110 V DC
Voltage250 V IEC 300 V CSA 300 V UL
Rated operational voltage limits88...121 V DC
[Uimp] rated impulse withstand voltage4 kV 1.2/50 µs)

All specifications

RUMF33FD additional specifications
ParameterValue
[Ie] rated operational current10 A at 277 V AC conforming to UL 10 A at 30 V DC conforming to UL 10 A at 277 V AC (same polarity) conforming to CSA 10 A at 30 V DC conforming to CSA 5 A at 250 V AC (NC) conforming to IEC 5 A at 28 V DC (NC) conforming to IEC 10 A at 250 V AC (NO) conforming to IEC 10 A at 28 V DC (NO) conforming to IEC
[Ithe] conventional enclosed thermal current10 A -40...131 °F (-40...55 °C)
IP degree of protectionIP40
Pollution degree3
Shock resistance10 gn 11 ms) in operation IEC 60068-2-27 10 gn 11 ms) not operating IEC 60068-2-27
Vibration resistance3 gn +/- 1 mm 10...150 Hz)5 cycles in operation 4 gn +/- 1 mm 10...150 Hz)5 cycles not operating
Contacts materialAgNi
Electrical durability100000 cycles resistive
Mechanical durability5000000 cycles
StandardsIEC 61810-1 CSA C22.2 No 14 UL 508
CategoryUS10CP221127
Reset time20 ms at nominal voltage
Status LEDWith
Test levelsLevel A group mounting
Shape of pinFlat
Operating rate<= 1200 cycles/hour under load
Operating time20 ms at nominal voltage
Average resistance7300 Ohm 20 °C +/- 15 %
Compatibility codeRUM
Operating positionAny position
Device presentationComplete product
Dielectric strength1500 V AC between contacts with micro disconnection 2500 V AC between coil and contact with reinforced 2000 V AC between poles with basic
Protection categoryRT I
Safety reliability dataB10d = 100000
Utilisation coefficient20 %
Maximum switching capacity2500 VA/280 W
Minimum switching capacity170 mW 10 mA, 17 V
Ambient air temperature for storage-40...185 °F (-40...85 °C)
Ambient air temperature for operation-40...131 °F (-40...55 °C)
MPN
RUMF33FD