Skip to main content
Schneider Electric RXM2LB2ED

Schneider Electric RXM2LB2ED

MPNRXM2LB2ED
Active

miniature plug-in relay - HARMONY RXM2L - 2 C/O - 48 V DC - 5 A - with LED

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

RXM2LB2ED key specifications
ParameterValue
TypeMiniature relay
Series nameRXM series
Control typeWithout lockable test button
Range of productHarmony Electromechanical Relays
Product or component typePlug-in relay
Contacts type and composition2 C/O
Maximum switching voltage250 V AC 28 V DC
Minimum switching voltage5 V subject to switching frequency, environment or expected reliability level etc
Drop-out voltage threshold>= 0.1 Uc DC
Coil voltage48 V DC
Voltage250 V IEC
Rated operational voltage limits38.4...52.8 V DC

All specifications

RXM2LB2ED additional specifications
ParameterValue
Load current5 A 250 V AC 5 A 28 V DC
Minimum switching current5 mA subject to switching frequency, environment or expected reliability level etc
[Ie] rated operational current2.5 A 28 V DC) NC IEC 2.5 A 250 V AC) NC IEC 5 A 28 V DC) NO IEC 5 A 250 V AC) NO IEC 5 A 24 V DC) NO IEC 5 A 220 V AC) NO IEC 5 A 28 V DC) UL 5 A 250 V AC) UL
[Ithe] conventional enclosed thermal current5 A -40...131 °F (-40...55 °C)
Pollution degree3
Shock resistance30 gnnot operating IEC 60068-2-27 10 gnin operation IEC 60068-2-27
Vibration resistance3 gn +/- 1 mm 10...50 Hz)operating IEC 60068-2-6 6 gn +/- 1 mm 10...50 Hz)not operating IEC 60068-2-6
Contacts materialSilver alloy (Ag/Ni)
Electrical durability200000 cycles resistive 23 °C 100000 cycles resistive at 55 °C
Mechanical durability20000000 cycles
StandardsCE IEC 61810-1 (iss. 2) UL 508
CategoryUS1CP4B22153
Status LEDWith
Test levelsLevel A group mounting
Shape of pinFlat (faston type)
Operating rate<= 18000 cycles/hour no-load
Average resistance2600 Ohm at 73 °F (23 °C) +/- 10 %
Operating positionAny position
Dielectric strength2000 V AC between coil and contact with basic insulation 2000 V AC between poles with basic insulation 1000 V AC between contacts with micro disconnection
Protection categoryRT I
Safety reliability dataB10d = 100000
Utilisation coefficient20 %
Average coil consumption0.9 W, DC
Maximum switching capacity1250 VA AC 140 W DC
Minimum switching capacity25 mW subject to switching frequency, environment or expected reliability level etc
Sale per indivisible quantity10
Ambient air temperature for storage-40...185 °F (-40...85 °C)
MPN