Torque and speed across the supply rail
The SH32052P11F2200: Nominal speed scales with the drive bus: 500 rpm on 115 V single-phase, 1000 rpm on 230 V single-phase, 2000 rpm on 400 V three-phase, and 2400 rpm on 480 V three-phase, which is the figure a panel designer uses to set the drive's speed-command ceiling for each install. Nominal torque follows the inverse — 545.2 lbf.in (61.6 N.m) at 115 V, 495.6 lbf.in (56 N.m) at 230 V, 337.2 lbf.in (38.1 N.m) at 400 V, and 251.4 lbf.in (28.4 N.m) at 480 V — so a 400 V three-phase pairing gives the practical working point of 7980 W nominal output power, while stepping up to 480 V trades torque for top-end speed. Continuous stall torque is 574.4 lbf.in (64.9 N.m) at 25.7 A across 115...480 V, which is the steady-state figure the drive's current loop has to hold when the rotor is commanded to a fixed position — i.e. the sizing basis for the servo amplifier's continuous-current rating.
SinCos Hiperface feedback and electrical interface
The electrical interface is a rotatable right-angled connector, letting the cable exit in any of four directions after the motor is bolted down — important in cabinets where the cable gland lands on a fixed side and the motor can be mounted in either orientation.
IP65/IP67 sealing and thermal envelope
Winding thermal limit is 266 °F (130 °C) copper-hot across 5 motor poles, with cooling by natural convection only — derating starts above the ambient curve the manufacturer publishes, and panel integrators typically budget 10–15 % continuous-torque margin when the motor is mounted inside an enclosure without assisted airflow.
Shaft, flange, and shaft-load envelope
Shaft end is a 1.5 in (38 mm) parallel-key shaft with a 0.4 in (10 mm) key, 3.1 in (80 mm) long, mounted on a 205 mm flange with a 180 mm centring collar at 4 mm depth and four 0.6 in (14 mm) mounting holes — the standard IEC mounting footprint that drops onto any gearbox or coupling rated for the torque class.
Sourcing posture for the SH32052P11F2200
Pricing and availability are confirmed against an RFQ: this code is quoted to order on the production BOM, with current lead time and volume pricing returned at quote time rather than posted as a list number.