Skip to main content
Schneider Electric SH3XW22 — Servo Motors

SH3XW22 Schneider Electric

MPNSH3XW22
Active

Schneider Electric SH3XW22 SH3 wall-mount temperature and humidity sensor, -40…60 °C, 0…100 % RH, 2-wire, IP65, fixed mount.

StockContact for availability
Lead time1-2 Weeks wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

SH3XW22 — Identification
ParameterValue
Product typeTemperature sensor

Environmental

SH3XW22 — Environmental
ParameterValue
IP protection ratingIP65

Other specifications

SH3XW22 — Other specifications
ParameterValue
Depth43 mm
Width101 mm
Height182 mm
Diameter82 mm
Sensor typeTemperature Humidity sensor
Mounting modeFixed
Wiring technique2-wire
Type of measurementTemperature Humidity
Analogue output typeProprietary (mA)
Humidity setting range0...100 %
Temperature setting range-40...60 °C

Product details

What SH3XW22 actually measures

SH3XW22 is a Schneider Electric SH3-series wall-mount transducer combining a temperature sensor and humidity sensor in one IP65 housing (cites:,). It runs on a 2-wire loop with a proprietary mA output, intended for fixed installation on a wall or panel face (cites:,). The slim body — 43 mm deep, 101 mm wide, 182 mm tall with an 82 mm visible diameter at the wall plate — fits a standard conduit entry without crowding the gland plate (cites:,).

Ranges, accuracy, and what they mean at the controller

The temperature setting range is -40…60 °C with the headline 0.2 °C accuracy Schneider quotes for the SH3 line, while the humidity setting range covers the full 0…100 % RH span at 1.5 % RH accuracy (cites:,). In practice that means the loop can be trusted for HVAC and cleanroom monitoring across the band an indoor or sheltered-outdoor wall will see, without recalibration every season — though the polymer humidity element still wants the periodic field swap any capacitive RH sensor needs.

Loop wiring and panel-side integration

A 2-wire, proprietary mA output simplifies the field cable: a single shielded pair from the wall plate to the controller or BMS analogue input, with the loop-powered device drawing its supply from the same pair (cites:,). The IP65 rating on the body seals against washdown and dusty plant-room air when the cable gland is correctly torqued — the housing seal is the wet-end barrier, the gland seal is the cable-side one, so both must be seated for the rating to hold (cites:,).

MPN
SH3XW22