Schneider Electric SOL40F3A160 — Miniature Circuit Breakers (MCB)

SOL40F3A160 EasyPact Solar MCCB, 160A, 36kA at 800V AC

MPNSOL40F3A160
Active

Schneider Electric EasyPact Solar MCCB, SOL40F3A160, 3-pole, 160A at 40°C, 36kA at 800V AC, TM-D trip unit, IP20, backplate mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

SOL40F3A160 — Identification
ParameterValue
Product range (series)EasyPact Solar MCCB
Product/component typeCircuit breaker
Device applicationDistribution
SOL40F3A160 — Ratings
ParameterValue
Rated current (In)160 A at 40 °C
Poles configuration3P
Rated operational voltage (Ue)800 V AC 50/60 Hz conforming to EN/IEC 60947-2
Rated insulation voltage (Ui)1250 V AC conforming to EN/IEC 60947-2
Rated impulse withstand voltage (Uimp)8 kV conforming to EN/IEC 60947-2
Utilisation categoryCategory A
Overvoltage categoryIII
SOL40F3A160 — Protection
ParameterValue
Trip unit technologyThermal-magnetic
Suitability for isolationYes conforming to EN/IEC 60947-2
Electrical durability (cycles)4000 cycles at 800 V In
Mechanical durability (cycles)20000 cycles
SOL40F3A160 — Mechanical
ParameterValue
Mounting supportBackplate
Control typeToggle
SOL40F3A160 — Environmental
ParameterValue
Operating ambient temperature-10...50 °C
Storage ambient temperature-35...85 °C
IP degree of protectionIP20 conforming to IEC 60529
Pollution degree3 conforming to IEC 60664-1
SOL40F3A160 — Approvals
ParameterValue
StandardsEN/IEC 60947-1 EN/IEC 60947-2 EN/IEC 60947-2 Annex H
SOL40F3A160 — Electrical
ParameterValue
[Icu] rated ultimate short-circuit breaking capacity36 kA Icu at 800 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity30 kA at 800 V AC 50/60 Hz conforming to EN/IEC 60947-2
SOL40F3A160 — Specifications
ParameterValue
[Ir] long-time protection pick-up adjustment range0.7...1 x In
Trip unit protection functionsLI

Product details

Solar-string molded case circuit breaker

The 36 kA breaking capacity at 800 V AC (performance level F) gives headroom for high-fault solar combiner boxes and inverter-side protection where available fault current runs high.

Above that, thermal derating applies — the TM-D unit has a thermal memory, so repeated overloads accumulate heat and shorten the trip time on the next event. This matters for solar strings where partial shading can cause sustained overcurrents below the magnetic threshold. Category A utilisation confirms it is not intended for cascaded selectivity with downstream breakers — coordination must be achieved through selective coordination studies, not built-in delay. Mechanical durability of 20,000 cycles and electrical durability of 4,000 cycles at rated voltage give a realistic service life for a distribution breaker that sees occasional switching, not daily motor starts. Power dissipation of 9 W per pole (27 W total at rated load) must be factored into enclosure thermal calculations, especially in sealed outdoor combiner boxes.

Connection pitch is 40 mm, matching standard busbar spacing for 3-pole breakers in panelboards. Mounting position is flexible — horizontal or vertical — which helps in tight enclosures where busbar orientation varies. Dimensions of 120 x 205 x 105 mm (W x H x D) fit standard MCCB cutouts in sheet-metal panels.

Frequently asked questions

What are the key ratings of SOL40F3A160?

Rated current 160 A at 40 °C, breaking capacity 36 kA at 800 V AC, 3-pole thermal-magnetic trip unit with LI protection.

What standards does SOL40F3A160 comply with?

It complies with EN/IEC 60947-1, EN/IEC 60947-2, and EN/IEC 60947-2 Annex H for isolation suitability.

Where can I buy SOL40F3A160?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

MPN
SOL40F3A160