Schneider Electric TSXPSY8500M
MPNTSXPSY8500M
Obsolete
100/240VAC 85W P.SUP.|100/240VAC 85W P.SUP.
$2,280.00 – $3,508.60Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Protection type | Internal fuse 4 A 5 x 20 mm time-delayed primary circuit Overload protection secondary circuit Overvoltage protection secondary circuit Short-circuit protection secondary circuit |
| Range of product | Modicon Premium Automation platform |
| Product or component type | Power supply module |
| Primary voltage | 100...120 V AC 85...140 V 200...240 V AC 170...264 V |
| Current at secondary voltage | 1.6 A 24 V DC sensor power supply 15 A 5 V DC |
| Input current | 1700 mA 100 V 500 mA 240 V |
| Inrush current | 30 A 100 V 60 A 240 V |
| Secondary power | 75 W 5 V DC |
| Total useful secondary power | 100 W 131 °F (55 °C) with fan module 77 W 140 °F (60 °C) 85 W 131 °F (55 °C) |
| Network frequency | 50/60 Hz |
| Network frequency limits | 47...63 Hz |
| IP degree of protection | IP20 |
All specifications
| Parameter | Value |
|---|---|
| Pollution degree | 2 |
| Relative humidity | 10...95 % without condensation for operation 5...95 % without condensation for storage |
| Operating altitude | 0...6561.68 ft (0...2000 m) |
| Standards | CSA C22.2 No 142 73/23/EEC 89/336/EEC 92/31/EEC CSA C22.2 No 213 Class I Division 2 Group D CSA C22.2 No 213 Class I Division 2 Group A UL 508 CSA C22.2 No 213 Class I Division 2 Group C CSA C22.2 No 213 Class I Division 2 Group B IEC 61131-2 93/68/EEC |
| Marking | CE |
| Category | US1PC2222558 |
| Module format | Double |
| It on activation | 0.15 A.s 100 V 0.15 A.s 240 V |
| Local signalling | 1 LED (green) for presence of sensor voltage (24V) 1 LED (green) for presence of voltages (OK) 1 LED (red) for battery fault (BAT) |
| I2t on activation | 15 A².s 100 V 8 A².s 240 V |
| Dielectric strength | 2000 V primary/earth 2000 V primary/secondary |
| Protective treatment | TC |
| Insulation resistance | >= 100 MOhm primary/ground >= 100 MOhm primary/secondary |
| Immunity to microbreaks | 10 ms |
| Ambient air temperature for storage | -13...158 °F (-25...70 °C) |
| Ambient air temperature for operation | 32...140 °F (0...60 °C) |
MPN