Schneider Electric VW3A7250 active infeed converter (AIC), 120 kW, 380-480 V, 185 A continuous output at 400 V, IP00, built-in unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

VW3A7250 — Electrical
ParameterValue
Network frequency50/60 Hz
VW3A7250 — Cable & Connector
ParameterValue
Connector type1 RJ45 for Modbus Male SUB-D 9 on RJ45 for CANopen
VW3A7250 — Mechanical
ParameterValue
Width310 mm
Height680 mm
Depth377 mm
VW3A7250 — Environmental
ParameterValue
IP protection ratingIP00
Operating ambient temperature45...60 °C (with current derating of 2 % per °C) -10...45 °C
Storage ambient temperature-25...70 °C
Relative humidity0...95 %
Operating altitude1000...3000 m with current derating 1 % per 100 m
Environmental class3K3 conforming to EN/IEC 60721-3-3 3C2 conforming to EN 60721-3-3 3S2 conforming to EN 60721-3-3
VW3A7250 — Approvals
ParameterValue
Conformance standardsEN/IEC 61800-5-1

Product details

The VW3A7250 is a Schneider Electric active infeed converter (AIC) rated 120 kW, designed to supply a regulated DC bus from a 380-480 V three-phase AC line while actively managing harmonics and enabling energy regeneration back to the mains. The unit is a built-in assembly (IP00) measuring 680 mm high by 310 mm wide by 377 mm deep, so it needs a clean enclosure with at least 500 cm² of air flow surface and forced convection cooling moving 400 m³/h through the power circuit.

Communication and control integration

The AIC includes a communication bridge with one RJ45 for Modbus and a male SUB-D 9 on RJ45 for CANopen, so it drops into a mixed-fieldbus line-up without a separate gateway card.

Lifecycle reality — obsolete, sourced to order

Available through independent distribution channels; quantities and pricing are confirmed at RFQ against the specific BOM line. For a project already designed around this AIC, the unit can be sourced as a last-time-buy or surplus procurement — confirm the install window and spares requirement at quote time.

Environmental and mechanical limits

Operates from -10 °C to 45 °C without derating; above 45 °C up to 60 °C, derate current 2 % per °C. Rated for 7 gn shock at 11 ms and vibration resistance of 1.5 mm at 3-10 Hz / 0.6 gn at 10-200 Hz per EN/IEC 60068-2-6, which covers normal industrial floor and conveyor line conditions. Altitude derating starts at 1000 m — above that, reduce current 1 % per 100 m. Relative humidity tolerance is 0-95 % non-condensing.

Frequently asked questions

What is the VW3A7250's continuous output current at 400 V?

185 A continuous at 400 V, with a 60-second overload capability of 1.2× nominal and a 2-second capability of 1.35× nominal.

What communication protocols does the VW3A7250 support?

Modbus via RJ45 and CANopen via a male SUB-D 9 on RJ45 connector. The unit includes a communication bridge option card for these fieldbuses.