Skip to main content
Schneider Electric XB6AGC5B

Schneider Electric XB6AGC5B

MPNXB6AGC5B
Active

SELECTOR SWITCH 250VAC 1.5A XB6|SELECTOR SWITCH 250VAC 1.5A XB6

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

XB6AGC5B key specifications
ParameterValue
Type of keylockKey 200
Range of productHarmony XB6
Type of operatorstay put
Product or component typeComplete selector switch
Contacts type and composition1 NO + 1 NC
Voltage250 V 3)IEC 60947-1
[Uimp] rated impulse withstand voltage4 kV IEC 60947-1
Short-circuit protection6 A cartridge fuse gG
[Ie] rated operational current3 A 120 V, AC-15, B300 IEC 60947-5-1 1.5 A 240 V, AC-15, B300 IEC 60947-5-1 0.1 A 250 V, DC-13, R300 IEC 60947-5-1 0.22 A 125 V, DC-13, R300 IEC 60947-5-1
IP degree of protectionIP65 IEC 60529
Mounting diameter0.6 in (16 mm)
Connections - terminalsFaston connectors 2.8 x 0.5 mm

All specifications

XB6AGC5B additional specifications
ParameterValue
Terminals description ISO n°1(13-14)NO (21-22)NC
Shock resistance30 gn 18 ms) half sine wave acceleration IEC 60068-2-27 50 gn 11 ms) half sine wave acceleration IEC 60068-2-27
Vibration resistance+/- 3 mm (f= 2...500 Hz) conforming to IEC 60068-2-6 5 gn (f= 2...500 Hz) conforming to IEC 60068-2-6
Electrical shock protection classClass II conforming to IEC 61140
Bezel materialPlastic
CAD overall depth3.1 in (80 mm)
CAD overall width0.7 in (18 mm)
Contacts materialSilver alloy (Ag/Ni)
CAD overall height0.7 in (18 mm)
Electrical durability1000000 cycles, AC-15 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C 1000000 cycles, DC-13 230 V 3600 cyc/h 0.5 IEC 60947-5-1 appendix C
Mechanical durability200000 cycles
StandardsIEC 60947-5-5 UL 508 JIS C8201-5-1 CSA C22.2 No 14 IEC 60947-1 JIS C 852 IEC 60947-5-1 JIS C8201-1
CategoryUS10CS222459
Operator profilekey switch
Positive openingWith IEC 60947-5-1 appendix K
Contact operationSlow-break
Device short nameXB6
Operating positionAny position
Protective treatmentTC
Electrical reliabilityΛ = 10exp(-8) 5 V 1 mA with confidence level of 90 % IEC 60947-5-4
Key withdrawal positionIn any position
Shape of signaling unit headRound
Operator position information2 positions 70°
Sale per indivisible quantity1
Ambient air temperature for storage-40...158 °F (-40...70 °C)
Ambient air temperature for operation-13...158 °F (-25...70 °C)
MPN