Schneider Electric XPSMC16ZPPACK
MPNXPSMC16ZPPACK
Obsolete
safety controller XPS-MC - 24 V DC - 16 input - 32 LEDs signalling
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →Specifications
| Parameter | Value |
|---|---|
| Output signal | 2 relays, 2 NO contacts (4 NO total) Solid state, 6, volt-free |
| Type of start | Configurable |
| Range of product | Preventa Safety automation |
| Input protection type | External fuse 16 A |
| Product or component type | Kit configurable safety controller |
| Minimum output voltage | 17 V relay output |
| Supply voltage | 24 V DC - 20...20 % |
| Coil voltage | 28.8 V |
| Voltage | 300 V 2)IEC 60647-5-1, DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60647-5-1, DIN VDE 0110 part 1 |
| Breaking capacity | 2 A 24 V static output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Minimum output current | 10 mA relay output |
All specifications
| Parameter | Value |
|---|---|
| Output thermal current | 4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other relay output |
| [Ith] conventional free air thermal current | 16 A relay output 6.5 A static output circuit |
| Power consumption in | 12 W |
| I/O channels | 16 |
| IP degree of protection | IP20 conforming to EN/IEC 60529 |
| Supported modbus function | 01 8-bit output data/32-bit input data 02 32-bit input data/8-bit output data 03 information and errors |
| Communication port protocol | Modbus 1 RJ45, serial link 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps Profibus 1 SUB-D 9-pin female, serial link 12 Mbps |
| Mounting support | Mounting plate |
| Response time | Configurable : 20 ms or 30 ms with software XPSMCWIN |
| Depth | 6.02 in (153 mm) |
| Width | 2.9 in (74 mm) |
| Height | 6.0 in (151.5 mm) |
| Standards | IEC 61508 EN/IEC 60947-5-1 EN/IEC 60204-1 EN/IEC 61496-1 EN 954-1/EN/ISO 13849-1 EN 1760-1/ISO 13856-1 EN 574/ISO 13851 |
| Parity | Even Modbus No Modbus Odd Modbus |
| Category | 22477-SAFETY MODULES (PREVENTA) |
| Data format | 1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode |
| Safety level | Can reach PL e/category 4 EN 954-1/EN/ISO 13849-1 Can reach SIL 3 IEC 61508 |
| Exchange size | 14 words |
| Kit composition | Safety controller Set of screw terminals Connection cable Printed packaging label 80 x 50 mm Configuration software USB/RS485 converter Profibus connectors Set of cage clamp terminals VDE slot screwdriver 2.5 x 75 mm Packaging small model for software configuration Ethernet cable 2m |
| Local signalling | 32 LEDs |
| Method of access | Slave |
| Function of module | Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring Monitoring safety stop at top dead centre on eccentric press Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 EN/IEC 61496 Two-hand control category 3 EN 574/ISO 13851 |
| Safety module name | XPSMC |
| Number of addresses | 1...125 Profibus 1...247 Modbus |
| Safety use category | Category 4 maximum EN 954-1/EN/ISO 13849-1 PLE maximum EN/ISO 13849-1 SIL 3 maximum IEC 61508 |
| Associated fuse rating | 16 A gL power supply 4 A gL relay output 6 A fast blow relay output |
| Maximum line resistance | 100 Ohm <6561.7 ft (2000 m) |
| Ambient air temperature for storage | -13...185 °F (-25...85 °C) |
| Synchronisation time between inputs | Depending on configuration selected |
| Ambient air temperature for operation | 14...131 °F (-10...55 °C) |
MPN