Schneider Electric XPSUAB31CC
MPNXPSUAB31CC
Active
safety module, Harmony XPSU, potential free 2 NC, NO NC, 2 PNP, 48 to 240V AC or DC, spring
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Type of start | Automatic/manual/monitored |
| Range of product | Harmony Safety Automation |
| Input (output type) | Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
| Input protection type | Internal, electronic |
| Electrical circuit type | NC pair PNP pair Antivalent pair OSSD pair |
| Product or component type | Safety module |
| Minimum output voltage | 15 V relay output |
| Supply voltage | 48...240 V AC/DC - 10...10 % |
| Voltage | 250 V 2)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV II IEC 60947-1 |
| Minimum output current | 10 mA relay output |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 2 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact |
All specifications
| Parameter | Value |
|---|---|
| [Ith] conventional free air thermal current | 3 A |
| Power consumption in | 6.5 VA 240 V AC 50/60 Hz |
| IP degree of protection | IP20 terminals)IEC 60529 IP40 housing)IEC 60529 IP54 mounting area)IEC 60529 |
| Mounting support | 35 mm symmetrical DIN rail |
| Connections - terminals | Removable spring terminal block, 0.2...2.5 mm² solid or flexible Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| Maximum wire resistance | 500 Ohm |
| Maximum response time on input open | 20 ms |
| Relative humidity | 5...95 % non-condensing |
| Depth | 4.7 in (120 mm) |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (100 mm) |
| Standards | IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard |
| Category | US1SAF222477 |
| Safety level | Can reach PL = c ISO 13849-1 Can reach SILCL 1 IEC 62061 Can reach SIL 1 IEC 61508 |
| Safety inputs | 1 safety input 24 V DC 5 mA |
| Safety outputs | 1 C/O |
| Control outputs | 2 on/off configurable pulsed output |
| Local signalling | LED (green) for power ON LED (red) for error LED (yellow) for start LED (yellow) for safety status LED (yellow) for safety input S12 LED (yellow) for safety input S13 |
| Function of module | Emergency stop monitoring 1-channel wiring Guard monitoring 1-channel wiring Monitoring 1 PNP sensor Monitoring two-hand control station type IIIA Magnetic switch monitoring Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE) Proximity sensor monitoring |
| Safety module name | XPSUAB |
| Input compatibility | Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 Antivalent pair ISO 14119 OSSD pair IEC 61496-1-2 Two-hand control EN 574/ISO 13851-III A 3-wire proximity sensors PNP |
| Associated fuse rating | 6 A gG relay output IEC 60947-1 |
| Safety reliability data | MTTFd >= 30 years ISO 13849-1 Dcavg < 60 % ISO 13849-1 PFHd = 1177E-09 1/h ISO 13849-1 HFT = 0 IEC 62061 PFHd = 1177E-09 1/h IEC 62061 SFF > 60% IEC 62061 HFT=0 IEC 61508-1 PFHd = 1177E-09 1/h IEC 61508-1 SFF > 60% IEC 61508-1 Type = B IEC 61508-1 |
| Safety module application | For electrical monitoring of two-hand control stations For application with safety switchover contact For emergency stop, guard and light curtain monitoring Monitoring antivalent contacts |
| Synchronisation time between inputs | 0.5 s 2.2 s |
| Ambient air temperature for operation | -13...131 °F (-25...55 °C) |
MPN