Schneider Electric XPSUAF33AC
MPNXPSUAF33AC
Active
safety module, Harmony XPSU, Cat 4, potential free 2 NC, NO NC, 2 PNP, 48 to 240V AC or DC, spring
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026
Specifications
| Parameter | Value |
|---|---|
| Type of start | Automatic/manual/monitored |
| Range of product | Harmony Safety Automation |
| Input (output type) | Semiconductor pulsed diagnostic output 24 V DC, 20 mA Z1, not safety-related |
| Input protection type | Internal, electronic |
| Electrical circuit type | NC pair PNP pair Antivalent pair OSSD pair |
| Product or component type | Safety module |
| Minimum output voltage | 15 V relay output |
| Supply voltage | 48...240 V AC/DC - 10...10 % |
| Voltage | 250 V 2)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV II IEC 60947-1 |
| Minimum output current | 10 mA relay output |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact |
All specifications
| Parameter | Value |
|---|---|
| [Ith] conventional free air thermal current | 8 A |
| Power consumption in | 6.5 VA 240 V AC 50/60 Hz |
| IP degree of protection | IP20 terminals)IEC 60529 IP40 housing)IEC 60529 IP54 mounting area)IEC 60529 |
| Mounting support | 35 mm symmetrical DIN rail |
| Connections - terminals | Removable spring terminal block, 0.2...2.5 mm² solid or flexible Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| Maximum wire resistance | 500 Ohm |
| Maximum response time on input open | 20 ms |
| Relative humidity | 5...95 % non-condensing |
| Depth | 4.7 in (120 mm) |
| Width | 0.9 in (22.5 mm) |
| Height | 3.9 in (100 mm) |
| Standards | IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard |
| Category | US1SAF222477 |
| Safety level | Can reach PL e/category 4 ISO 13849-1 Can reach SILCL 3 IEC 62061 Can reach SIL 3 IEC 61508 |
| Safety inputs | 2 safety input 24 V DC 5 mA |
| Safety outputs | 3 NO |
| Control outputs | 3 on/off configurable pulsed output |
| Local signalling | LED (green) for power ON LED (red) for error LED (yellow) for start LED (yellow) for safety status LED (yellow) for safety input S12 LED (yellow) for safety input S22 |
| Function of module | Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches Monitoring 2 PNP sensors Magnetic switch monitoring Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE) Proximity sensor monitoring |
| Safety module name | XPSUAF |
| Input compatibility | Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 Antivalent pair ISO 14119 OSSD pair IEC 61496-1-2 3-wire proximity sensors PNP |
| Associated fuse rating | 10 A gG NO relay output circuit IEC 60947-1 |
| Safety reliability data | MTTFd > 30 years ISO 13849-1 Dcavg >= 99 % ISO 13849-1 PFHd = 1.61E-09 ISO 13849-1 HFT = 1 IEC 62061 PFHd = 1.61E-09 IEC 62061 SFF > 99% IEC 62061 HFT = 1 IEC 61508-1 PFHd = 1.61E-09 IEC 61508-1 SFF > 99% IEC 61508-1 Type = B IEC 61508-1 |
| Safety module application | Monitoring antivalent contacts For emergency stop, guard and light curtain monitoring |
| Ambient air temperature for storage | -13...185 °F (-25...85 °C) |
| Synchronisation time between inputs | 0.5 s 2 s 4 s |
MPN
XPSUAF33AC