Found 541 results for “signal isolator 0-10V” (filtered) (60 products, 0 articles).
ABB CC-E I/I analog signal converter, 1-channel loop-powered current isolator, 0-20 mA / 4-20 mA, DIN rail mount, type 1SVR010200R1600.
ABB CC-U/RTD Universal signal converter, 1SVR040003R0600, for PT10/PT100/PT1000 sensors, 110-240 VAC supply, 3-way isolation, ±0.2% accuracy.
Omron G6A-274P-ST-US-DC24 PCB mount signal relay, 24V DC coil, DPDT, 2A switching current, 0.45 kg.
Omron G6B series general-purpose relay, 4PST contact form, 24V DC coil, 2 A contact rating at 250V AC / 30V DC, PCB-mount 4-pin package.
ABB 1SVR405521R6100 CR-S series general purpose relay, 110/125 VDC coil, current lifecycle stage, Relays & Sockets subcategory.
Omron G2RV-SL700 DC24 (DC21) general purpose relay, 24 VDC coil, SPDT contact arrangement, 6 A resistive / 2.5 A inductive switching, screw terminal, -40 to 55°C operating range.
ABB CR series interface relay, 1SVR405601R2000, plug-in DPDT, 8 A at 250 VAC, 120 VAC coil, 8-blade base, socket mount.
Omron G7L-2A-BJ-AC24 general purpose relay, 24 VAC coil, 0.11 kgs, PCB/socket mount, 2-pole form A.
Transformer protection (2 wdg.) 8 curr. trans., 16 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Transformer protection (3 windings) 12 Current tr., 3 AFD (Arc Flash Detector) 24 BI, 13 BO (incl. 3 HSBO) Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC-interfaces S12 enclosure
Transformer protection (2 wdg.) 8 curr. trans., 16 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S12 enclosure
Transformer prot. 7SR54 8 curr. trans., 4 volt. trans., 22 BI, 12 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S12 enclosure
Transformer protection (2 wdg.) 8 curr. trans., 4 volt. trans. 37 BI, 18 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure incl. conformal coating
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 24 BI, 14 BO Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces, S12 enclosure
Overcurrent time protection 7SR51 4 curr. trans., 23 BI, 12 BQ Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 9 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S6 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 9 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S6 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 39 BI, 20 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 14 BI, 10 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 19 BI, 12 BQ Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51, 4 curr. trans., 4 volt. trans., 24 BI, 14 BO Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces, S12 enclosure, including conformal coating
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 39 BI, 20 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 14 BI, 10 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S12 enclosure
Overcurrent time protection 7SR51 4 curr. trans., 23 BI, 12 BQ Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC interf. S12 enclosure
Overcurrent time protection 7SR51, 4 curr. trans., 8 BI, 6 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S6 enclosure, including conformal coating
Overcurrent time protection 7SR51 4 curr. trans., 8 BI, 6 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S6 enclosure
Directional time-overcurrent protection 7SR51,5 curr. trans., 4 volt. trans., 22 BI, 12 BO, Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC-interfaces, S12 enclosure
Directional time-overcurrent protection 7SR51,5 curr. trans., 4 volt. trans., 22 BI, 12 BO, Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Directional time-overcurrent protection 7SR51, 4 curr. trans., 4 volt. trans., 9 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S6 enclosure, including conformal coating
Directional time-overcurrent protection 7SR51, 4 curr. trans., 4 volt. trans., 9 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf., S6 enclosure, including conformal coating
Transformer prot. 7SR54 8 curr. trans., 4 volt. trans., 8 TSI (Temperature Sensor Input), 22 BI, 12 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S12 enclosure
Overcurrent time protection 7SR51, 4 curr. trans., 38 BI,18 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S12 enclosure, including conformal coating
Transformer prot. 7SR54 8 curr. trans., 4 volt. trans., 3 AFD (Arc Flash Detector), 22 BI, 15 BO (incl. 3 HSBO) Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S12 enclosure
Transformer prot. 7SR54 8 curr. trans., 4 volt. trans., 22 BI, 12 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC ports, S12 enclosure, including conformal coating
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 24 BI, 14 BO Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC-interfaces, S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 9 BI, 11 BO (incl. 3 HSBO), 3 AFD (Arc Flash Detector), Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC-interfaces, S6 enclosure
Directional time-overcurrent protection 7SR51, 4 curr. trans., 4 volt. trans., 19 BI, 12 BO, Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC interf., S12 enclosure, including conformal coating
Directional time-overcurrent protection 7SR51, 5 curr. trans., 4 volt. trans., 17 BI, 10 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S12 enclosure, including conformal coating
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 19 BI, 12 BQ Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC interf. S12 enclosure
Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 9 BI, 11 BO (incl. 3 HSBO), 3AFD (Arc Flash Detector), Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S6 enclosure
Directional time-overcurrent protection 7SR51, 4 curr. trans., 4 volt. trans., 9 BI, 11 BO (incl. 3 HSBO), 3AFD (Arc Flash Detector), Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces, S6 enclosure, including conformal coating
Overcurrent time protection 7SR51 4 curr. trans., 13 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S6 enclosure
Transformer protection (2 wdg.) 8 curr. trans., 4 volt. trans. 12 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
Transformer protection (2 wdg.) 8 curr. trans., 4 volt. trans. 12 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC interf. S12 enclosure
Transformer protection (3 windings) 12 Current tr., 24 BI, 10 BO Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC interfaces S12 enclosure
Transformer protection (3 windings) 12 Current tr., 24 BI, 10 BO Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces S12 enclosure
Transformer protection (3 windings) 12 Current tr., 4 Voltage tr., 35 BI, 16 BO, Standard interface: 1 x USB (front), RS485 (rear) + 2 x RJ45 interfaces S12 enclosure
Transformer protection (3 windings) 12 Current tr., 4 Voltage tr., 35 BI, 16 BO, Standard interface: 1 x USB (front), RS485 (rear) + 2 x optical LC interfaces S12 enclosure
Overcurrent time protection 7SR51 4 curr. trans., 13 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S6 enclosure
Motor protection 7SR57, 4 curr. trans., 3 AFD (Arc Flash Detector), 13 BI, 11 BO (incl. 3 high speed BO) Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC-interface, S6 enclosure incl. conformal coating
Motor protection 7SR57, 4 curr. trans., 3 AFD (Arc Flash Detector), 13 BI, 11 BO (incl. 3 high speed BO) Standard interface: 1 x USB (front), RS 485 (rear) + 2 x optical LC-interface, S6 enclosure