Skip to main content
Siemens 3RH2140-1AP60 — Contactors

Siemens 3RH2140-1AP60 SIRIUS Aux Contactor, 4 NO, S00

MPN3RH2140-1AP60
Active

Siemens SIRIUS 3RH2140-1AP60 auxiliary contactor, size S00, 4 NO, 45 mm width, 73 mm depth, screw and snap-on DIN rail mount.

$120.57Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2140-1AP60 — Identification
ParameterValue
Contactor frame sizeS00
3RH2140-1AP60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2140-1AP60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz220 V
3RH2140-1AP60 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2140-1AP60 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH2140-1AP60 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH2140-1AP60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2140-1AP60 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH2140-1AP60 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

S00 auxiliary contactor for SIRIUS contactors

The 3RH2140-1AP60: It occupies 45 mm width on the DIN rail, with 73 mm depth and 57.5 mm height, fitting standard panel layouts for S00 auxiliary modules.

What it switches and where it fits

This is an auxiliary contactor, not a main contactor. It provides 4 instantaneous NO contacts for signaling, interlocking, or control circuits in motor starter groups or PLC output isolation.

Mounting and wiring clearances

Minimum clearances: 10 mm upwards/downwards/forwards, 6 mm to the side. These ensure adequate arc quenching and cooling in polluted environments (degree of pollution 3). Terminals accept solid or stranded wires: 2x 0.5–1.5 mm², 2x 0.75–2.5 mm², or 2x 4 mm². Use ferrules on stranded conductors for reliable spring-cage connection. Rated at 50/60 Hz with a tolerance band of 0.8–1.1 at 50 Hz and 0.85–1.1 at 60 Hz.

Frequently asked questions

What is the closest functional second-source?

The peer MPNs 3RT2027-1AP60, -1AF00, -1AK60 are main contactors, not auxiliary contactors. This 3RH2140-1AP60 is designed as a supplementary 4-NO auxiliary block; there is no exact functional substitute in the peer list.

MPN
3RH2140-1AP60