Siemens SIRIUS power contactor, Size S0, 3RT2028-1AN60, 45 mm width, screw-type coil terminals, auxiliary switch, screw and snap-on mounting on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2028-1AN60 — Identification
ParameterValue
Contactor frame sizeS0
3RT2028-1AN60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V22 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V5 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2028-1AN60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz200 V
3RT2028-1AN60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2028-1AN60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 125A (690V,100kA), aM: 50A (690V,100kA), BS88: 125A (415V,80kA)
Short-circuit coordination type 2, fusegG: 50A (690V,100kA), aM: 25A (690V, 100kA), BS88: 50A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2028-1AN60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2028-1AN60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2028-1AN60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2028-1AN60 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth97 mm
3RT2028-1AN60 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

The contactor is rated for AC-3 switching at up to 750 operations per hour, and AC-4 at 250 operations per hour. AC-3 covers starting and running squirrel-cage motors; AC-4 covers inching and plugging duty. If your application involves frequent jogging, the 250 cycles/h ceiling on AC-4 is the limiting figure — not the AC-3 number. Coil consumption is 0.25 A at 50 Hz and 0.28 A at 60 Hz — a small enough draw that a standard 24 VDC power supply can drive multiple contactors without oversizing, but check the inrush if you are ganging several on one output. Wire range accepts solid or stranded conductors from 1 to 10 mm², and also allows two conductors per terminal (2x 0.5…1.5 mm² or 2x 0.75…2.5 mm²). That dual-conductor capability is useful for daisy-chaining control wiring without extra terminal blocks. The auxiliary switch is built in (yes/no: yes), with contact ratings that vary by voltage: 10 A at 24 V, 2 A at 48/60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, 0.6 A at 440 V. These are the make/break capacities for the auxiliary contacts — useful for PLC inputs or indicator lamps, but not for power switching. The storage range is wider because the contactor is not dissipating coil heat; the operating range is the one that governs panel ambient.

Frequently asked questions

What is 3RT2028-1AN60's listed depth (97 mm) on this component line?

The depth is 97 mm, which is the dimension that matters for gland-plate clearance or enclosure depth behind the DIN rail.

What is 3RT2028-1AN60's listed solid (1... 10 mm²) on this component line?

The wire range accepts solid or stranded conductors from 1 to 10 mm², and also allows two conductors per terminal (2x 0.5…1.5 mm² or 2x 0.75…2.5 mm²).

Will 3RT2028-1AN60 drop into a panel that was specified around 3RT2016-1AG62 without rewiring?

Both are SIRIUS Size S0 contactors on the same 45 mm DIN-rail footprint, so the mechanical fit is identical. The 3RT2028-1AN60 includes an auxiliary switch; the 3RT2016-1AG62 may not. Check the coil voltage and auxiliary contact configuration on your BOM — the terminal layout and wire range are the same, so no rewiring is needed if the coil matches.

What compliance documentation does this brand provide for 3RT2028-1AN60 (RoHS, REACH, UL, IEC)?

As a SIRIUS product, Siemens typically provides RoHS, REACH, UL, and IEC declarations. The evidence does not list specific cert numbers, but these are standard for the SIRIUS line and can be requested at quote time.

MPN