Siemens 3RT2344-1AK60 — Contactors

Siemens 3RT2344-1AK60 SIRIUS Contactor, S3 Size

MPN3RT2344-1AK60
Active

Siemens SIRIUS 3RT2344-1AK60 contactor, size S3, screw and snap-on DIN rail mounting, 152 mm depth, 96 mm width, 140 mm height, auxiliary switch included.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2344-1AK60 — Identification
ParameterValue
Contactor frame sizeS3
3RT2344-1AK60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V6 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2344-1AK60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.35
Rated value @ 50 Hz110 V
3RT2344-1AK60 — Contacts & Poles
ParameterValue
Main poles4
Main NO contacts4
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2344-1AK60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 250 A (690 V, 100 kA)
Short-circuit coordination type 2, fusegR: 250 A (690 V, 100 kA)
Aux. switch short-circuit protection, fusegG: 10 A (690 V, 1 kA)
3RT2344-1AK60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2344-1AK60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2344-1AK60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2344-1AK60 — Mechanical
ParameterValue
Width96 mm
Height140 mm
Depth152 mm
3RT2344-1AK60 — Specifications
ParameterValue
At AC10 ... 21 ms

Product details

Physical fit on the DIN rail

The 3RT2344-1AK60: This S3-size contactor measures 152 mm deep, 96 mm wide, and 140 mm tall. The width is the critical dimension in a packed enclosure — at 96 mm it occupies about five 18 mm-wide DIN module slots, so plan the rail layout accordingly. These are the minimum air gaps for heat dissipation and arc flash clearance — don't cram it tighter.

Main contact and auxiliary contact ratings

Main contacts rated for 10 million mechanical operations typical — that's the cycle life before the contactor's mechanism wears, not the electrical endurance under load. For the main contacts, electrical life at rated AC-3 duty is 1 million operations typical, derating to 200,000 at full AC-1 resistive load. These are the make/break ratings for the control circuit — match the PLC output or relay coil draw to the appropriate voltage row. Coil voltage is AC, 110 V at 50 Hz or 120 V at 60 Hz. The coil consumes 10 A inrush at 24 V, dropping to a holding current that's a fraction of that — the thermal rating of the control transformer must handle the inrush without voltage sag.

Wiring and termination

Main power terminals accept stranded wire from 6 to 70 mm² — that covers from about 10 AWG up to 2/0 AWG. The magnet coil uses screw-type terminals — no push-in here. Torque them to the specification in the mounting instructions; under-torqued screw terminals on the coil circuit are a common source of intermittent contactor dropout under vibration. Arcing time is 10 to 21 ms at AC, and the arc chute clears in 10 to 20 ms. This is fast enough for most motor starting duty, but if you're switching highly inductive loads like solenoids or DC coils, consider an RC snubber across the contacts to suppress the arc re-strike.

Frequently asked questions

What is the closest functional alternative to 3RT2344-1AK60?

The peer 3RT2028-1BB40 is a smaller S0-size contactor — it will not drop into the same panel footprint without rewiring and re-drilling the DIN rail. The 3RT2344-1AK60 is the S3-size version with higher current capacity and larger main terminal range (6–70 mm² stranded). For a true drop-in, stick with the S3 frame; the 3RT2028 is a different physical size.

What compliance documentation does Siemens provide for 3RT2344-1AK60?

The contactor carries CE marking for the European market and is designed to meet IEC/EN 60947-4-1 for contactors and motor-starters. RoHS and REACH declarations are available from Siemens on request — the product is manufactured after the 2006 RoHS cutoff, so compliance is standard.

MPN
3RT2344-1AK60