Skip to main content
Siemens 3SE5232-0PC05 — Limit Switches

Siemens 3SE5232-0PC05

MPN3SE5232-0PC05
Active

position switch plastic enclosure according to DIN EN 50047, 31 mm device connection 1 x (M20 x 1.5) 2 NO/1 NC slow-action contacts rounded plunger, form B

$15.24Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3SE5232-0PC05 — Identification
ParameterValue
Product designationMechanical position switches
Product brand nameSIRIUS
3SE5232-0PC05 — Switching & Safety
ParameterValue
Positive opening functionYes
Auxiliary NO contacts2
Auxiliary NC contacts1
Circuit principleslow-action contacts
Switching function designpositive opening
Active principlemechanical
Safety-related switching contacts1
Suitable as safety switchYes
Switching contact designmechanical
Safety-related interface connectorwithout
3SE5232-0PC05 — Mechanical
ParameterValue
Actuating element designRounded plunger, plastic plunger
Standard-compliant actuator headEN 50047, design B
Switch head shaperounded
Repeat accuracy0.05 mm
Mechanical service life (typ. operating cycles)15 000 000
Enclosure materialplastic
Switch head enclosure materialplastic
Mounting positionany
Fastening methodscrew fixing
Length75.7 mm
Width31 mm
Minimum actuating force20 N
Enclosure coatingOther types
Housing design standardblock, narrow
3SE5232-0PC05 — Environmental
ParameterValue
IP protection ratingIP65
Operating temperature range-25 ... +85 °C
Storage temperature range-40 ... +90 °C
Shock resistance (IEC 60068-2-27)30g / 11 ms
Pollution degreeclass 3
3SE5232-0PC05 — Wiring
ParameterValue
Electrical connection typescrew-type terminals
Interface connector designwithout
Conductor cross-section, finely stranded (with ferrule)1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²)
Conductor cross-section, solid1x (0.5 ... 1.5 mm²), 2x (0.5 ... 0.75 mm²)
Cable entry type1x (M20 x 1.5)
3SE5232-0PC05 — Electrical
ParameterValue
Rated insulation voltage250 V
Thermal current10 A
Rated operating frequency50 ... 60 Hz
Rated impulse withstand voltage4 kV
Rated current at 24 V3 A
Rated current at 125 V0.55 A
DIAZED gG fuse link, continuous current6 A
C-characteristic MCB, continuous current1 A; for a short-circuit current smaller than 400 A
Quick DIAZED fuse link, continuous current10 A; for a short-circuit current smaller than 400 A
3SE5232-0PC05 — Specifications
ParameterValue
According to IEC 60068-2-60.35 mm/5g
Of The Supplied Switching Contacts3SE5000-0PA00
MPN
3SE5232-0PC05