Siemens 3VA1050-3ED36-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-3ED36-0AE0 SENTRON MCCB, 50 A, 75.6 kA at 24

MPN3VA1050-3ED36-0AE0

Siemens SENTRON 3VA1050-3ED36-0AE0, molded case circuit breaker, 3-pole, 50 A, interrupting capacity 75.6 kA at 240 VAC, TM210 thermal-magnetic release, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1050-3ED36-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10503ED360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1050-3ED36-0AE0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.14.6 W
3VA1050-3ED36-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1050-3ED36-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-3ED36-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts4
3VA1050-3ED36-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-3ED36-0AE0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

3-pole 50 A MCCB with 75.6 kA interrupting at 240 V

The Siemens 3VA1050-3ED36-0AE0 is a SENTRON molded case circuit breaker (MCCB) rated for 50 A continuous at 40 °C ambient, with a thermal-magnetic TM210 overcurrent release. Its interrupting capacity reaches 75.6 kA at 240 VAC, 52.5 kA at 415 VAC, and 32 kA at 440 VAC — figures that determine the available fault current it can safely clear without upstream coordination failure. At 500 V and 690 V the rating drops to 7.5 kA, so verify the system voltage against the site's SCCR study before specifying.

The 50 A rating holds flat from 40 °C through 50 °C ambient. Above that it derates: 49 A at 55 °C, 48 A at 60 °C, 46 A at 65 °C, and 45 A at 70 °C. If the breaker sits in a crowded enclosure with internal heat rise, use the 70 °C figure for worst-case sizing — that 45 A limit is the real-world continuous current the TM210 release will pass without nuisance tripping. Dimensions are 70 mm deep, 76.2 mm wide, 130 mm high. The 76.2 mm width (3 inches) is the standard 3-pole MCCB footprint for DIN-rail or panel-mount installation. No trip indicator is fitted on this variant — fault status is read from the auxiliary switch block or the handle position.