Siemens SENTRON 3VA1050-3ED42-0AA0, 4-pole molded case circuit breaker (MCCB), 50 A rated current, TM210 thermal-magnetic release, breaking capacity 75.6 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1050-3ED42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1050-3ED42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C49 A
Current at 60 °C48 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.14.6 W
3VA1050-3ED42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1050-3ED42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1050-3ED42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1050-3ED42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1050-3ED42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

What this 4-pole MCCB delivers

It carries 75.6 kA breaking capacity at 240 V and 52.5 kA at 415 V, dropping to 32 kA at 440 V and 7.5 kA at 500 V and 690 V. The 4-pole design makes it suitable for three-phase plus neutral protection in distribution panels or as a main breaker in industrial switchboards.

Thermal derating matters in a hot control room

At 55 °C it derates to 49 A, at 60 °C to 48 A, at 65 °C to 46 A, and at 70 °C to 45 A. In a cement plant control room that runs 50–55 °C near the kiln, that derating is real — you lose 1–2 A of headroom. The 14.6 W maximum power loss adds to the enclosure heat load; factor it into the panel cooling calc.

Frequently asked questions

What is the breaking capacity of 3VA1050-3ED42-0AA0 at 415 V?

52.5 kA at 415 V. At 240 V it is 75.6 kA, at 440 V it is 32 kA, and at 500 V or 690 V it is 7.5 kA.

Where can I buy 3VA1050-3ED42-0AA0 and how is it quoted?

This MCCB is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — both are confirmed at quote time.

What compliance documentation is available for this MCCB?

The SENTRON 3VA series carries IEC 60947-2 certification. RoHS and REACH compliance documentation is available from Siemens. The IP40 front protection rating is also listed.

MPN
3VA1050-3ED42-0AA0