Skip to main content
Siemens 3VA1050-3ED42-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1050-3ED42-0AD0 SENTRON MCCB, 50A, 4-Pole, TM210

MPN3VA1050-3ED42-0AD0

Siemens SENTRON 3VA1050-3ED42-0AD0, 4-pole molded case circuit breaker, 50 A rated continuous current (Iu), TM210 thermal-magnetic overcurrent release, line protection version, 3 auxiliary switches HQ, interrupting ratings from 75.6 kA at 240 V to 7.5 kA at 690 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA1050-3ED42-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA1050-3ED42-0AD0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C50 A
Current at 45 °C50 A
Current at 50 °C50 A
Current at 55 °C48 A
Current at 60 °C47 A
Current at 65 °C46 A
Current at 70 °C45 A
Switching capacity classN
Breaking capacity at 240 V75.6 kA
Breaking capacity at 415 V52.5 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 690 V7.5 kA

Protection & Trip Unit

3VA1050-3ED42-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210

Construction & Connection

3VA1050-3ED42-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA1050-3ED42-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts3

Environmental

3VA1050-3ED42-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA1050-3ED42-0AD0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm

Product details

What this MCCB carries — and what it doesn't

The Siemens 3VA1050-3ED42-0AD0 is a SENTRON 4-pole molded case circuit breaker rated for 50 A continuous current (Iu) at 40 °C, with a TM210 thermal-magnetic trip unit — fixed thermal, fixed magnetic, no electronic adjustment. Interrupting capacity is 75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V. It ships with three HQ auxiliary switches built in, no undervoltage release, no ground-fault monitoring, no communication module, and no voltage trip. This is a straight line-protection breaker for a panel that needs a fixed-trip 50 A feed.

Thermal derating and panel fit

The 50 A rating holds flat from 40 °C to 50 °C, then steps down: 48 A at 55 °C, 47 A at 60 °C, 46 A at 65 °C, 45 A at 70 °C. Ambient inside the enclosure matters — if the panel runs hot, you lose 5 A by 70 °C. Dimensions are 130 mm tall, 101.6 mm wide, 70 mm deep. Front protection is IP40, so it's fine inside a clean panel but not for washdown zones. No N-conductor protection on this variant.

Frequently asked questions

What are the interrupting ratings for this MCCB?

75.6 kA at 240 V, 52.5 kA at 415 V, 32 kA at 440 V, and 7.5 kA at 690 V.

Where can I buy 3VA1050-3ED42-0AD0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Does this breaker include an undervoltage release or ground fault monitoring?

No. It ships without an undervoltage release, without ground fault monitoring, and without a communication module. It's a straight thermal-magnetic line protection breaker.

MPN
3VA1050-3ED42-0AD0