Skip to main content
Siemens 3VA1192-5MG32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1192-5MG32-0AA0 MCCB, 3-pole, 12.5 A, 187 kA at 2

MPN3VA1192-5MG32-0AA0
Active

Siemens SENTRON 3VA1192-5MG32-0AA0, molded case circuit breaker, 3-pole, starter protection design, rated 12.5 A, 187 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1192-5MG32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1192-5MG32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C12.5 A
Current at 45 °C12.5 A
Current at 50 °C12.5 A
Current at 55 °C12.1 A
Current at 60 °C11.9 A
Current at 65 °C11.5 A
Current at 70 °C11 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.5.7 W
3VA1192-5MG32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM110M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1192-5MG32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1192-5MG32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1192-5MG32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1192-5MG32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Rated 12.5 A at 40 °C, it holds that current flat through 50 °C, then derates gradually to 11 A at 70 °C. The interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 440 V — numbers that tell you this breaker is sized for high-fault industrial panels, not light commercial gear. The 76.2 mm width (3 in) and 70 mm depth (2.76 in) mean it fits standard SENTRON mounting patterns — same footprint as other 3VA frame sizes — so a panel laid out for a 3VA1110 family breaker should accept this unit without re-drilling the gland plate.

Frequently asked questions

What are the key interrupting ratings for 3VA1192-5MG32-0AA0?

It breaks 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V.

What is the depth of 3VA1192-5MG32-0AA0?

The depth is 70 mm (2.76 in).

What is the width of 3VA1192-5MG32-0AA0?

The width is 76.2 mm (3 in).

Where can I buy 3VA1192-5MG32-0AA0?

Sourced and quoted to order against an RFQ through independent distribution — availability and current pricing confirmed at quote time.

MPN
3VA1192-5MG32-0AA0