Skip to main content
Siemens 3VA1104-5MG32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1104-5MG32-0AA0 SENTRON MCCB, 4 A, 187 kA at 240

MPN3VA1104-5MG32-0AA0
Active

Siemens SENTRON 3VA1104-5MG32-0AA0, 3-pole molded case circuit breaker, 4 A rated current, 187 kA breaking capacity at 240 V AC, starter protection design with TM110M release.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1104-5MG32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1104-5MG32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C4 A
Current at 45 °C4 A
Current at 50 °C4 A
Current at 55 °C4 A
Current at 60 °C4 A
Current at 65 °C4 A
Current at 70 °C4 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.5.4 W
3VA1104-5MG32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM110M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1104-5MG32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1104-5MG32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1104-5MG32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1104-5MG32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VA1104-5MG32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated 4 A continuous — flat across the full 40 °C to 70 °C ambient range — with a TM110M thermal-magnetic overcurrent release. The starter protection design means it's built to coordinate with a contactor for motor starting duty; the TM release handles overloads, and the magnetic element clears short-circuits. Breaking capacity is the headline here: 187 kA at 240 V AC, 121 kA at 415 V, 75.6 kA at 440 V, and 7.5 kA at both 500 V and 690 V. The steep drop above 440 V reflects the physics of arc extinction in a compact frame; at 690 V the 7.5 kA rating still covers downstream faults in a well-coordinated system.

The power loss is 5.4 W maximum, which is modest for a 4 A MCCB and won't drive enclosure derating in a typical panel.

Frequently asked questions

Will 3VA1104-5MG32-0AA0 drop into a panel specified for 3VA1110-5ED32-0AA0?

Both are 3-pole SENTRON 3VA MCCBs with the same 70 mm depth, 76.2 mm width, and 130 mm height (-), so the mechanical footprint is identical. The difference is the current rating and release type — verify the BOM's required ampacity before swapping.

MPN
3VA1104-5MG32-0AA0