Skip to main content
Siemens 3VA2140-7HK42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-7HK42-0AA0 SENTRON MCCB, 40 A, 4-Pole, 240 V

MPN3VA2140-7HK42-0AA0
Active

Siemens SENTRON 3VA2140-7HK42-0AA0, molded case circuit breaker, 4-pole, 40 A, ETU340 release, breaking capacity 330 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-7HK42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2140-7HK42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V53 kA
Power loss, max.1.6 W
3VA2140-7HK42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
3VA2140-7HK42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-7HK42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2140-7HK42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-7HK42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in
Depth (in)3.4 in

Product details

Line protection MCCB with full-temperature rating

The Siemens 3VA2140-7HK42-0AA0 is a SENTRON molded case circuit breaker rated for line protection, 4-pole, with a continuous current Iu of 40 A that holds flat across the entire operating range — 40 A at 40 °C, 45 °C, 50 °C, 55 °C, 60 °C, 65 °C, and 70 °C. That means no derating curve to chase in a warm panel; the 40 A rating is good right up to the maximum ambient of 70 °C. Breaking capacity is specified per voltage: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 53 kA at 690 V. At 415 V, the 242 kA figure covers most industrial distribution panels with high fault current — no need for current-limiting fuses upstream for typical installations within that range.

ETU340 release and selectivity

The overcurrent release is an ETU340, a microprocessor-based unit with adjustable N-conductor protection (OFF or 100%) and a fixed time delay tr of 1300 ms. The fixed tr simplifies coordination — you know the long-time delay is 1.3 s, no guesswork on the curve. The 20 000 electrical endurance cycles (latching) suit it for frequent switching applications like main incomers or feeder breakers in production lines.

Frequently asked questions

What is the breaking capacity of 3VA2140-7HK42-0AA0 at 415 V?

242 kA at 415 V, and the same at 440 V. At 240 V it reaches 330 kA.

Does this MCCB derate at higher ambient temperatures?

No — the 40 A rating holds flat from 40 °C up to 70 °C ambient. No derating needed within that range.

Where can I buy the 3VA2140-7HK42-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.

MPN
3VA2140-7HK42-0AA0