Siemens 3VA2163-5HN36-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HN36-0AB0 SENTRON MCCB, 63 A, 187 kA at 240

MPN3VA2163-5HN36-0AB0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3-pole, 63 A rated continuous current, 187 kA breaking capacity at 240 VAC, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-5HN36-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635HN360AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA2163-5HN36-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-5HN36-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5HN36-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5HN36-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2163-5HN36-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5HN36-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Breaking capacity is the deciding parameter: 187 kA at 240 VAC covers high-fault service-entrance positions on 240/120 V split-phase panels; 121 kA at 415 VAC and 440 VAC suits European 400 V distribution; 75.6 kA at 500 VAC fits 480 V industrial feeders; the 3.7 kA at 690 VAC is a coordination-limited value for 690 V drives or mining gear where upstream current-limiting fuses handle the high fault. The line-protection design designation means the thermal-magnetic trip curve is calibrated for cable and busbar protection, not motor inrush — pair it with a contactor or starter for motor branch circuits.

Panel integration

Dimensions: 181 mm height, 105 mm width, 86 mm depth. No undervoltage release and no trip indicator — if your safety circuit requires UVR for loss-of-voltage protection, specify a variant with that option. The 4 W maximum power loss is low enough that no forced ventilation is required in a standard IP54 enclosure, but verify the internal temperature rise if ganged with other high-current breakers.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-5HN36-0AB0?

Pricing and stock are confirmed at quote time against an RFQ through independent distribution channels. Submit a request for current commercial terms.

What is the breaking capacity of 3VA2163-5HN36-0AB0 at 415 V?

121 kA at 415 VAC, which covers most European 400 V distribution transformer secondary faults without upstream fusing.

Does 3VA2163-5HN36-0AB0 include an undervoltage release?

No, this variant does not have an undervoltage release. If UVR is required for your safety circuit, choose a 3VA2 variant with that option.

MPN
3VA2163-5HN36-0AB0