Siemens 3VA2163-5HN36-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5HN36-0AE0 SENTRON MCCB, 63 A, 187 kA IC

MPN3VA2163-5HN36-0AE0

Siemens SENTRON 3VA2163-5HN36-0AE0, molded case circuit breaker, 3-pole, 63 A rated continuous current Iu, ETU350 electronic trip unit, interrupting rating 187 kA at 240 V, 4 auxiliary switches HQ, IP40 front protection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5HN36-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-5HN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2163-5HN36-0AE0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V4.25 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5HN36-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350

Construction & Connection

3VA2163-5HN36-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5HN36-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2163-5HN36-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5HN36-0AE0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Line protection MCCB with ETU350 — what the ratings mean for your panel

The Siemens SENTRON 3VA2163-5HN36-0AE0 is a 3-pole molded case circuit breaker rated for line protection, carrying a continuous current Iu of 63 A that holds flat from 40 °C through 50 °C — no derating needed in a warm enclosure until you cross 55 °C, where it steps down to 60.6 A. The interrupting rating is the headline here: 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. That 187 kA figure at 240 V means this breaker handles high-fault scenarios common on the secondary side of large distribution transformers without needing a current-limiting upstream device — it's sized for switchboard and main feeder duty, not just branch protection. The ETU350 electronic trip unit gives you adjustable long-time, short-time, and instantaneous pickup settings plus ground-fault alarm capability (though this variant ships without ground-fault monitoring fitted). Four HQ auxiliary switches come integrated, so you get status feedback without bolting on an external accessory block.

Mounting and integration — DIN-rail or panel-mount, IP40 front

Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — standard SENTRON 3VA2 footprint that drops into existing panel cutouts or onto the mounting plate without re-drilling. The IP40 front protection means it's splash-safe from the front face in a closed enclosure; the busbar connections and terminals are inside the panel, not exposed. Rated insulation voltage Ui is 800 V, so it's comfortable on 480 V and 600 V class systems with margin. Maximum power loss is 4 W — negligible for thermal budgeting inside a crowded cabinet. Operating temperature range is -25 °C to 70 °C, storage from -40 °C to 80 °C. The mechanical endurance is 20,000 operations — that's the latching mechanism life, not the electrical switching life under load.

Frequently asked questions

What is the interrupting rating of 3VA2163-5HN36-0AE0 at 240 V?

The interrupting rating is 187 kA at 240 V, 121 kA at 415 V and 440 V, 79 kA at 500 V, and 4.25 kA at 690 V. The 187 kA figure at 240 V covers high-fault scenarios on large transformer secondaries.

What trip unit does 3VA2163-5HN36-0AE0 use?

It uses the ETU350 electronic trip unit with adjustable long-time, short-time, and instantaneous settings. This variant ships without ground-fault monitoring fitted.

Where can I buy 3VA2163-5HN36-0AE0 and how is it quoted?

This part is sourced and quoted to order through independent distribution. Submit an RFQ for current pricing and availability — confirmed at quote time, no published stock figures.

MPN
3VA2163-5HN36-0AE0