Skip to main content
Siemens 3VA2163-6HK36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-6HK36-0AA0 SENTRON MCCB, 63 A, 3-Pole, 242 k

MPN3VA2163-6HK36-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2163-6HK36-0AA0, 3-pole, 63 A rated continuous current, ETU340 electronic trip unit, interrupting capacity 242 kA at 240 VAC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-6HK36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-6HK36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-6HK36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-6HK36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-6HK36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-6HK36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-6HK36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Line protection MCCB with ETU340 trip unit

The Siemens SENTRON 3VA2163-6HK36-0AA0 is a 3-pole molded case circuit breaker rated for 63 A continuous current, designed for line protection in distribution panels. Interrupting capacity reaches 242 kA at 240 VAC, dropping to 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The continuous current rating holds flat at 63 A across the entire ambient temperature range from 40 °C up to 70 °C — no derating needed as the panel warms, which simplifies panel design and avoids nuisance tripping in a crowded enclosure.

The 3VA2 series is the current-generation SENTRON platform, so replacement concerns are minimal for new builds. No last-time-buy window or phase-out notice is active on this order code.

Dimensions are 105 mm wide, 181 mm high, 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures without re-drilling. If you need those options, the 3VA2 platform offers them on other order codes within the same frame size.

Frequently asked questions

Where can I buy 3VA2163-6HK36-0AA0 and get a price?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial offer.

What is the interrupting capacity of this MCCB at 240 V?

The interrupting capacity is 242 kA at 240 VAC, which covers high-fault locations like main service entrances or transformer secondaries.

Does this breaker require derating at high ambient temperatures?

No. The 63 A continuous rating holds flat from 40 °C up to 70 °C ambient — no derating needed as the panel warms.

MPN
3VA2163-6HK36-0AA0