Skip to main content
Siemens 3VA2225-5HL32-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-5HL32-0AG0 SENTRON MCCB, 250 A, 3-Pole

MPN3VA2225-5HL32-0AG0

Siemens SENTRON 3VA2225-5HL32-0AG0, molded case circuit breaker, 3-pole, 250 A rated continuous current, 187 kA breaking capacity at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2225-5HL32-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2225-5HL32-0AG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C241 A
Current at 60 °C232 A
Current at 65 °C222 A
Current at 70 °C213 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.48 W
3VA2225-5HL32-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2225-5HL32-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-5HL32-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-5HL32-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-5HL32-0AG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2225-5HL32-0AG0 — 250 A MCCB, Active Line Protection

Its breaking capacity runs from 187 kA at 240 V down to 4.5 kA at 690 V, giving you selectivity headroom across common low-voltage levels without cascading upstream.

Breaking Capacity by Voltage Level

At 415 V and 440 V the breaker holds 121 kA; at 500 V it still delivers 75.6 kA.

Auxiliary Switching and Monitoring

This variant ships with one auxiliary switch and one trip-alarm switch (HP type) — enough for remote status feedback and fault annunciation without an additional add-on module.

The breaker measures 105 mm wide by 181 mm tall by 86 mm deep — a standard SENTRON 3VA2 footprint that fits existing panel cutouts and busbar spacing for 3-pole MCCBs in that amp class. The 86 mm depth leaves clearance for rear-connected busbars or cable lugs in a typical 600 mm deep enclosure.

Frequently asked questions

Where can I buy 3VA2225-5HL32-0AG0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What are the key ratings of this MCCB?

250 A continuous rating, 3-pole, breaking capacity of 187 kA at 240 V, 121 kA at 415/440 V, 75.6 kA at 500 V, and 4.5 kA at 690 V.

What is the depth of 3VA2225-5HL32-0AG0?

86 mm (3.39 in).

MPN
3VA2225-5HL32-0AG0