Skip to main content
Siemens 3VA2225-6JP32-0LK0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6JP32-0LK0 SENTRON MCCB, 250 A, 3-Pole, 242

MPN3VA2225-6JP32-0LK0

Siemens SENTRON 3VA2225-6JP32-0LK0, molded case circuit breaker, 3-pole, 250 A, interrupting rating 242 kA at 240 V, ETU550 electronic trip unit, line protection version.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2225-6JP32-0LK0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2225-6JP32-0LK0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W

Protection & Trip Unit

3VA2225-6JP32-0LK0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2225-6JP32-0LK0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2225-6JP32-0LK0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2225-6JP32-0LK0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2225-6JP32-0LK0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries — and where it fits

The Siemens SENTRON 3VA2225-6JP32-0LK0 is a 3-pole molded case circuit breaker rated 250 A continuous at 40 °C, with an ETU550 electronic trip unit configured for line protection. Its interrupting ratings hit 242 kA at 240 V and 187 kA at 415 V, which puts it in the high-fault-current tier — sized for main feeders or large sub-distribution where the available fault current is serious. The 105 mm width and 181 mm height match the standard SENTRON 3VA frame footprint, so it swaps into an existing 3VA panel cutout without re-drilling the gland plate.

Thermal derating and panel integration

Full 250 A rating holds through 50 °C ambient. Above that it derates linearly: 238 A at 55 °C, 225 A at 60 °C, down to 200 A at 70 °C. If your panel runs hot — say a non-ventilated enclosure next to a furnace line — size the load accordingly. The 86 mm depth leaves room for rear-access wiring in a standard 600 mm deep enclosure. Auxiliary contact configuration ships as 1 auxiliary switch + 1 trip alarm + 1 electrical alarm switch (HQ type), which covers status feedback to a PLC without adding a separate contact block.

Frequently asked questions

What is 3VA2225-6JP32-0LK0's listed depth?

86 mm (3.39 in).

What is 3VA2225-6JP32-0LK0's listed width?

105 mm (4.13 in).

MPN