Skip to main content
Siemens 3VA2225-6JQ32-0CC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2225-6JQ32-0CC0 SENTRON MCCB, 250 A, 3-Pole, 242

MPN3VA2225-6JQ32-0CC0

Siemens SENTRON 3VA2225-6JQ32-0CC0, molded case circuit breaker, 3-pole, 250 A, interrupting rating 242 kA at 240 V AC, line protection design, with undervoltage release and two auxiliary switches.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2225-6JQ32-0CC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2225-6JQ32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2225-6JQ32-0CC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C250 A
Current at 45 °C250 A
Current at 50 °C250 A
Current at 55 °C238 A
Current at 60 °C225 A
Current at 65 °C213 A
Current at 70 °C200 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.50.5 W
3VA2225-6JQ32-0CC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU560
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
Grounding protection functionYes
3VA2225-6JQ32-0CC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2225-6JQ32-0CC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2225-6JQ32-0CC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2225-6JQ32-0CC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for high-fault panels

The Siemens SENTRON 3VA2225-6JQ32-0CC0 is a 3-pole molded case circuit breaker rated 250 A at 40 °C, designed for line protection in distribution panels. Its interrupting rating hits 242 kA at 240 V AC — that's the short-circuit current it can safely clear without welding contacts or rupturing the case, so it handles high-fault service-entrance or sub-feed positions where upstream transformer capacity is large. The 250 A continuous rating means it carries that load continuously at 40 °C ambient; above that, the thermal derating curve drops to 200 A at 70 °C, which matters if the breaker sits in a hot enclosure near other heat sources. This MCCB includes an undervoltage release (UVR) that trips the breaker if supply voltage drops below a set threshold — standard for safety circuits where a loss of control voltage must open the main disconnect. It also carries two auxiliary switches (HQ type) for remote status indication back to a PLC or annunciator panel. The basic switch variant is 3VA2225-6JQ32-0AA0; this -0CC0 suffix adds the UVR and the aux switches as factory-fitted options, so you don't have to field-install add-on modules.

Panel fit

Dimensions: 105 mm wide, 181 mm high, 86 mm deep. That's a standard 3-pole MCCB footprint for a 250 A frame — it fits a typical DIN-rail or panel-mount base without crowding adjacent breakers. The 50.5 W maximum power loss at full load means the enclosure needs some ventilation or derating if packed tightly; a sealed stainless-steel box with no airflow will run hot, so plan for that in the thermal calculation.

MPN