Skip to main content
Siemens 3VA2580-5HL32-0AB0 — Molded Case Circuit Breakers (MCCB)

3VA2580-5HL32-0AB0 SENTRON MCCB, 800 A, 187 kA at 240 V

MPN3VA2580-5HL32-0AB0

Siemens SENTRON 3VA, molded case circuit breaker, 3-pole, 800 A, ETU320 electronic trip unit, 187 kA at 240 V, 121 kA at 415 V, 53 kA at 690 V, IP40 front, 120 × 210 × 320 mm.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2580-5HL32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2580-5HL32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C800 A
Current at 45 °C800 A
Current at 50 °C800 A
Current at 55 °C800 A
Current at 60 °C800 A
Current at 65 °C767 A
Current at 70 °C703 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V53 kA
Power loss, max.135 W
3VA2580-5HL32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2580-5HL32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2580-5HL32-0AB0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
3VA2580-5HL32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2580-5HL32-0AB0 — Mechanical
ParameterValue
Height320 mm
Width210 mm
Depth120 mm
Height (in)12.6 in
Width (in)8.3 in

Product details

Its 800 A continuous current rating holds flat from 40 °C to 60 °C before derating to 767 A at 65 °C and 703 A at 70 °C — useful when the breaker sits in a warm enclosure near other heat sources. Breaking capacity is the headline number here: 187 kA at 240 V, 121 kA at 415 V, and 53 kA at 690 V. The ETU320 trip unit gives adjustable long-time pickup (Ir) from 320 A to 800 A and short-time pickup (Ii) from 1200 A to 8000 A, with time delays from 0.5 to 17 seconds. That selectivity range lets you coordinate downstream breakers so only the faulted branch clears. Physical footprint is 120 mm deep, 210 mm wide, 320 mm tall — standard for an 800 A frame. The IP40 front rating means tools or fingers won't reach live parts in an enclosed panel, but the body itself isn't sealed against washdown.

The 210 mm width matches the busbar pitch for 3-pole breakers in most switchgear lineups; the 120 mm depth leaves room for rear-connected bus risers.

MPN
3VA2580-5HL32-0AB0