Siemens SENTRON 3VM1110-3ED32-0AA0 MCCB, 100A, 76kA at 240V

MPN3VM1110-3ED32-0AA0
Active

Siemens SENTRON 3VM1110-3ED32-0AA0, 3-pole molded case circuit breaker, 100 A at 40 °C, 76 kA at 240 V, TM210 trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1110-3ED32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VM1110-3ED32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V76 kA
Breaking capacity at 415 V53 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V12 kA
Power loss, max.25 W
3VM1110-3ED32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VM1110-3ED32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1110-3ED32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1110-3ED32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1110-3ED32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

Line protection breaker with TM210 trip

Breaking capacity hits 76 kA at 240 VAC, 53 kA at 415 VAC, and 32 kA at 440 VAC — figures that cover most industrial distribution panels. The TM210 designation means the thermal pickup is fixed at 100 A. No undervoltage release, no ground-fault module, no communication. Insulation voltage rated 800 V.

At 76.2 mm wide, 130 mm tall, and 70 mm deep, the 3VM1110-3ED32-0AA0 fits the standard SENTRON 3-pole MCCB footprint. Front IP40 protection handles basic panel dust; the breaker is intended for enclosed installation inside a switchboard or distribution box. Power dissipation maxes at 25 W at rated load — account for that heat in the enclosure thermal calculation.

MPN