Skip to main content
Siemens 3VM1110-3ED12-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1110-3ED12-0AA0 SENTRON MCCB, 1-Pole, 100 A, 53 k

MPN3VM1110-3ED12-0AA0
Active

Siemens SENTRON 3VM1110-3ED12-0AA0, 1-pole molded case circuit breaker, 100 A (40 °C), 53 kA at 240 V, TM210 thermal-magnetic release, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1110-3ED12-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VM1110-3ED12-0AA0 — Ratings
ParameterValue
Number of poles1
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V53 kA
Breaking capacity at 415 V8 kA
Power loss, max.8 W
3VM1110-3ED12-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VM1110-3ED12-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1110-3ED12-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1110-3ED12-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1110-3ED12-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width25.4 mm
Depth70 mm
Height (in)5.12 in
Width (in)1 in
Depth (in)2.76 in

Product details

Above that, it begins a gentle derating curve: 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. The 8 W maximum power loss is modest for a 1-pole 100 A device, so it won't cook adjacent components in a tightly packed DIN-rail assembly.

Mechanical fit and panel integration

At 25.4 mm wide (1 inch), 130 mm tall, and 70 mm deep, this single-pole MCCB fits a standard 25 mm module slot on the DIN rail.

Frequently asked questions

What is the depth of 3VM1110-3ED12-0AA0?

The depth is 70 mm (2.76 inches), measured from the mounting surface to the front of the breaker body.

MPN