Skip to main content
Siemens 3VM1112-4GE42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1112-4GE42-0AA0 SENTRON MCCB, 125 A, 121 kA at 24

MPN3VM1112-4GE42-0AA0
Active

Siemens SENTRON 3VM1112-4GE42-0AA0, 4-pole molded case circuit breaker, 125 A, TM220 release, 121 kA at 240 VAC, 70 mm depth.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1112-4GE42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1112-4GE42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V76 kA
Breaking capacity at 440 V53 kA
Breaking capacity at 500 V12 kA
Power loss, max.23 W
3VM1112-4GE42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1112-4GE42-0AA0 — Construction & Connection
ParameterValue
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1112-4GE42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1112-4GE42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1112-4GE42-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.1 in
Width (in)4 in
Depth (in)2.8 in

Product details

The Siemens 3VM1112-4GE42-0AA0 is a 4-pole SENTRON molded case circuit breaker with a TM220 thermal-magnetic release, rated 125 A continuous at 40 °C and delivering 121 kA interrupting capacity at 240 VAC. The interrupting curve drops to 76 kA at 415 V and 53 kA at 440 V, so it still holds its own on 400 V-class distribution.

Above that it steps down gradually: 122 A at 55 °C, 120 A at 60 °C, 117 A at 65 °C, and 114 A at 70 °C. If your enclosure sits near a heat source or in a non-conditioned space, that 114 A floor at 70 °C tells you the breaker still carries a solid margin on a 100 A feeder. The LI protection curve (long-time and instantaneous) with adjustable li max to 1,250 A gives you some tuning room for motor inrush or transformer magnetizing current without nuisance tripping.

Installation notes

Rated insulation voltage 690 V.

MPN
3VM1112-4GE42-0AA0