Skip to main content
Siemens 5SJ4304-7HG42 — 3-Pole MCB (DIN Rail)

Siemens 5SJ4304-7HG42 SENTRON MCB, 3P C-curve, 10 kA

MPN5SJ4304-7HG42
Active

Siemens SENTRON 5SJ4304-7HG42, miniature circuit breaker, 3-pole, C-curve, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 400 V AC, 60 V DC, 3 MW units, DIN rail mount.

$129.54Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SJ4304-7HG42 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SJ4304-7HG42 — Protection
ParameterValue
Tripping characteristic (curve)C
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-215 kA
Overvoltage category3
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
5SJ4304-7HG42 — Electrical
ParameterValue
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.8 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
5SJ4304-7HG42 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height121 mm
Depth70 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodon standard mounting rail
SealableYes
Accepts supplementary devicesYes
5SJ4304-7HG42 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Vibration resistance (IEC 60068-2-6)±1 mm at 5 to 25 Hz; 50 m/s² at 25 to 150 Hz

Product details

Rated 400 V AC and 60 V DC, it delivers 10 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2. Terminal tightening torque is 3.5 Nm for Cu conductors.

It avoids nuisance trips from brief inrush while still clearing hard faults. The 400 V AC rating suits three-phase line-to-line circuits; the 60 V DC rating covers control-voltage rails and battery-backed supplies. The 3-pole design switches all three phases simultaneously — no neutral pole. The breaker is sealable (padlockable handle) for lockout/tagout compliance. Halogen-free and silicon-free construction matters in clean-room or high-reliability environments where outgassing can contaminate optics or contacts.

The 3-module-width footprint (54 mm) occupies three 18 mm slots. Depth of 70 mm leaves clearance for wiring behind the panel door. IP20 protection with conductors connected;

Frequently asked questions

What is 5SJ4304-7HG42's listed depth?

The depth is 70 mm, with an installation depth also listed as 70 mm.

What is 5SJ4304-7HG42's listed width?

The width is 54 mm, corresponding to 3 modular width units (each 18 mm).

Will 5SJ4304-7HG42 drop into a panel specified around 5SY4304-7CV without rewiring?

Both are 3-pole C-curve MCBs on a 54 mm DIN-rail footprint, so the mechanical fit is the same. The 5SJ4304-7HG42 carries a 10 kA (EN 60898) / 15 kA (IEC 60947-2) rating, while the 5SY4304-7CV is a different series — verify the breaking capacity and terminal type match your panel schedule before swapping.

What compliance documentation does Siemens provide for 5SJ4304-7HG42?

The part is halogen-free and silicon-free. It is rated for pollution degree 3 and overvoltage category 3. The manufacturer typically provides CE, RoHS, and REACH declarations; specific certificates (UL, CSA) should be confirmed at quote time.

Where can I buy 5SJ4304-7HG42?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SJ4304-7HG42