Siemens 5SL4420-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL4420-6 SENTRON MCB, 4P B-20A 10kA 400V

MPN5SL4420-6
Active

Siemens SENTRON 5SL4420-6, 4-pole miniature circuit breaker, B-curve, 20 A rated at 30 °C, 10 kA breaking capacity per EN 60898 and IEC 60947-2, 400 V AC, 4 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4420-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4420-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC20 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL4420-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SL4420-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4420-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)+55 °C, max. 95% humidity

Product details

The Siemens 5SL4420-6 is a 4-pole miniature circuit breaker from the SENTRON family, with a B tripping characteristic rated 20 A at 30 °C (18.94 A at 40 °C, 17.24 A at 55 °C). It breaks fault currents up to 10 kA per both EN 60898 and IEC 60947-2 at 400 V AC, and carries a maximum 440 V AC in multi-phase operation. The 4 MW (72 mm) width and 76 mm depth mean it occupies four standard 18 mm DIN-rail slots — a common footprint for a 4P residential or light-commercial distribution board. With a mechanical service life of 10 000 operating cycles and an IP20 rating (with connected conductors), this is a standard panelboard MCB for residential buildings and infrastructure, not a motor-protection or high-inrush device.

The 70 mm installation depth (76 mm overall) clears most shallow gland plates. Degree of pollution 2 and overvoltage category III are standard for fixed-installation distribution boards. Touch protection is provided on the line-side terminals. Temperature derating is published: at 40 °C the rated current drops to 18.94 A, at 45 °C to 18.4 A, and at 55 °C to 17.24 A. The maximum operating temperature is 75 °C; minimum is -40 °C, which covers cold-chain and outdoor telecom shelters.

The product function includes neutral conductor switching: no — this is a 4-pole breaker that switches all four poles, but the neutral is not switched separately (it is a 4P, not a 3P+N with a switched neutral).

Frequently asked questions

Where can I buy 5SL4420-6 and what is the lead time?

The 5SL4420-6 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 5SL4420-6's depth and width for panel planning?

The depth is 76 mm (70 mm installation depth) and the width is 72 mm — four standard 18 mm modular units on a DIN rail.

What compliance documentation is available for 5SL4420-6?

The breaker is halogen-free and silicon-free, rated IP20 with connected conductors, and carries a degree of pollution 2 and overvoltage category III per IEC standards. It is designed for residential buildings and infrastructure per the manufacturer's suitability statement.

Will 5SL4420-6 drop into a panel specified for 5SL6132-6MB?

Both are 4-pole SENTRON MCBs on the same DIN-rail footprint, but the 5SL6132-6MB is a C-curve device while the 5SL4420-6 is a B-curve. If the panel was wired for a C-curve breaker, the 5SL4420-6 will physically fit and electrically connect, but the lower inrush tolerance of the B curve may cause nuisance tripping on loads with high starting currents.

MPN
5SL4420-6