Siemens 5SL4640-8 — 4-Pole MCB (DIN Rail)

Siemens 5SL4640-8 SENTRON MCB, 4P D-curve 40 A, 10 kA

MPN5SL4640-8
Active

Siemens SENTRON 5SL miniature circuit breaker, 4-pole (3P+N), D tripping characteristic, 40 A rated at 30 °C, 10 kA breaking capacity per EN 60898 and IEC 60947-2, 400 V AC, 4 MW units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4640-8 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4640-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC40 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
5SL4640-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SL4640-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4640-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)+55 °C, max. 95% humidity
5SL4640-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Rated 40 A at 30 °C and 400 V AC, it delivers a 10 kA breaking capacity under both EN 60898 and IEC 60947-2 — enough for residential and light commercial infrastructure panels where high inrush loads (transformers, motor starters) are present. The D-curve means it tolerates short-duration surges up to 10–20× rated current before tripping, so nuisance trips on startup are rare.

The 40 A rating is at 30 °C ambient; at 40 °C it derates to 37.89 A, at 45 °C to 36.8 A, and at 55 °C to 34.47 A. If your panel runs warm — say, a crowded DIN-rail enclosure — size the upstream load accordingly. The 10 kA SCCR (both EN 60898 and IEC 60947-2) tells you this breaker safely interrupts a fault up to 10 kA at 400 V without welding contacts or cascading failure upstream.

Installation depth is 70 mm; total depth 76 mm. Mounting position is unrestricted — horizontal, vertical, or upside-down on the rail — and the housing is sealable, halogen-free, and silicon-free.

Frequently asked questions

What is the breaking capacity of the 5SL4640-8?

10 kA per both EN 60898 and IEC 60947-2 at 400 V AC. That covers most residential and light commercial distribution panels.

Where can I buy the 5SL4640-8 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

Will the 5SL4640-8 drop into a panel specified for a 5SL6550-7BB?

Both are 4-pole SENTRON 5SL MCBs on the same DIN-rail footprint (4 MW, 72 mm wide). The 5SL4640-8 is a 40 A D-curve; the 5SL6550-7BB is a different rating/curve. If the panel was built for the same pole count and width, it will physically fit without rewiring — but verify the load current and tripping characteristic match your circuit.

What compliance documentation does Siemens provide for the 5SL4640-8?

The part carries EN 60898 and IEC 60947-2 ratings, overvoltage category III, pollution degree 2, and is halogen-free and silicon-free. Standard Siemens declarations of conformity (CE, UKCA) and material compliance (RoHS, REACH) are available on request.