Skip to main content
Siemens 5SN4316-7CN — 3-Pole MCB (DIN Rail)

Siemens 5SN4316-7CN SENTRON MCB, 3P, C, 16 A, 10 kA

MPN5SN4316-7CN

Siemens SENTRON 5SN4316-7CN, 3-pole miniature circuit breaker, C-curve, 16 A rated at 400 V AC, 10 kA breaking capacity per EN 60898, 3 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SN4316-7CN — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
5SN4316-7CN — Protection
ParameterValue
Tripping characteristic (curve)C
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree2
5SN4316-7CN — Electrical
ParameterValue
Rated current (AC)16 A
Rated voltage (AC, multi-phase)440 V
5SN4316-7CN — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
SealableYes
5SN4316-7CN — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes

Product details

SENTRON 5SN4316-7CN — 16 A C-curve MCB, 3-pole, 400 V

The Siemens SENTRON 5SN4316-7CN is a 3-pole miniature circuit breaker with C-curve tripping characteristic, rated 16 A at 400 V AC and 10 kA breaking capacity per EN 60898. The 10 kA SCCR at 400 V matches the typical fault level at the service entrance or sub-distribution board; upstream coordination with a higher-rated main breaker or fuse is the standard selectivity practice.

Thermal derating and ambient range

Rated 16 A at 30 °C ambient, the 5SN4316-7CN derates to 15.15 A at 40 °C, 14.71 A at 45 °C, 14.26 A at 50 °C, and 13.79 A at 55 °C. In a sealed enclosure or near heat-generating equipment, the 40 °C figure governs the practical load — a 15 A continuous load is the safe limit in a 40 °C panel.

Snap-on DIN rail mount, any position. Installation depth 70 mm, overall depth 76 mm — the extra 6 mm accounts for the terminal screws and wire bend radius.

Frequently asked questions

What is the breaking capacity of 5SN4316-7CN?

10 kA per EN 60898 at 400 V AC, with a maximum operating voltage of 440 V AC for multi-phase operation.

Where can I buy 5SN4316-7CN?

Sourced and quoted to order against an RFQ through independent distribution — availability and current pricing confirmed at quote time.

Will 5SN4316-7CN drop into a panel specified for 5SL4363-7?

Yes — the 5SN4316-7CN shares the same 76×54×90 mm footprint, 3-pole C-curve, 16 A rating, and 10 kA breaking capacity as the 5SL4363-7. The primary difference is that the 5SN series omits the supplementary-device slot and the 10,000-cycle mechanical life rating carried by the 5SL series; for standard branch-circuit protection the 5SN4316-7CN is a direct dimensional and functional fit.

MPN
5SN4316-7CN