Siemens 5SU9336-7CN06 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SU9336-7CN06 SENTRON RCBO, 6 A, C-Char, 30 mA, Type

MPN5SU9336-7CN06

Siemens SENTRON 5SU9336-7CN06 RCBO, 1P+N, Type A, 30 mA, C-Characteristic, In: 6 A, Un AC: 230 V, Icn: 6 kA per EN 60898 / 10 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SU9336-7CN06 — Electrical Ratings
ParameterValue
Number of poles3
Overvoltage categoryIII
5SU9336-7CN06 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9336-7CN06 — Mechanical
ParameterValue
Mounting positionany
Width in modular units2
Maximum75 °C
Minimum-40 °C
Width108 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9336-7CN06 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9336-7CN06 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

It combines overcurrent protection (C-curve, 6 A rated at 30 °C) with residual current detection (30 mA, Type A) in a single 2-module-wide unit. That means one device handles both thermal-magnetic trip for overloads and short-circuits, and ground-fault interruption for sinusoidal AC and pulsating DC residual currents.

C-curve characteristic means the magnetic trip fires at 5 to 10 times In (30–60 A for this 6 A unit), suited for mixed resistive and moderate inductive loads like lighting circuits, small motors, and control transformers. The 30 mA residual sensitivity is the standard for personal protection against fatal shock in most IEC-based codes. Type A detection covers both pure AC fault currents and pulsating DC — the kind you get from single-phase rectifiers in electronics or LED drivers. The 4 kV rated surge voltage (impulse withstand) means it survives switching transients and nearby lightning-induced spikes without nuisance tripping or damage.

Snaps onto DIN rail, 2 module widths. Mounting position is unrestricted. Supply can feed from top or bottom. Depth is 77 mm with 70 mm installation depth. Halogen-free and silicon-free.

Frequently asked questions

What does Type A residual current detection mean?

Type A detects both sinusoidal AC fault currents and pulsating DC — the kind produced by single-phase rectifiers in electronics, LED drivers, and switched-mode power supplies. Standard AC-only RCDs may not trip on pulsating DC.

MPN