Siemens 5SU9346-1CN10 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SU9346-1CN10 RCBO, 4P C-10A 30mA 6kA

MPN5SU9346-1CN10

Siemens SENTRON 5SU9346-1CN10, RCD-operated circuit breaker, 4-pole, tripping characteristic C, rated current 10 A, residual current 30 mA, breaking capacity 6 kA.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SU9346-1CN10 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SU9346-1CN10 — Identification
ParameterValue
Product designationRCD-operated circuit breaker
Product design / constructionInstantaneous
5SU9346-1CN10 — Mechanical
ParameterValue
Mounting positionany
Width in modular units7
Maximum75 °C
Minimum-40 °C
Width126 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SU9346-1CN10 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors
5SU9346-1CN10 — Electrical
ParameterValue
Tripping Characteristic ClassC

Product details

It is rated 10 A with a C tripping characteristic and 30 mA residual current sensitivity, breaking capacity 6 kA per EN 60898 and IEC 60947-2. The 30 mA AC-type residual current detection covers line-to-ground faults on standard sinusoidal AC circuits.

The 10 A rating holds at 30 °C ambient; it derates to 9.1 A at 40 °C, 8.7 A at 45 °C, 8.3 A at 50 °C, and 7.8 A at 55 °C. In a crowded distribution board with multiple RCBOs ganged, the effective current per pole drops — size the downstream load against the derated figure for the enclosure's internal temperature, not the nameplate 10 A. The device occupies 7 modular width units (126 mm wide) and installs 70 mm deep into the panel. Snap-on DIN rail mounting, any orientation. IP20 applies only when the distribution board is closed and conductors are connected — no exposed terminals during operation.

Frequently asked questions

How do I get current pricing and availability for 5SU9346-1CN10?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for confirmed availability and current pricing at quote time.

What is the closest functional second-source for 5SU9346-1CN10?

The 5SU9326-1CN16 is a functional peer within the same SENTRON RCBO family — same 4-pole, C-curve, 30 mA residual current form factor. Verify the rated current and breaking capacity match your BOM before substituting.

What are the key ratings of 5SU9346-1CN10?

4-pole RCBO, 10 A rated current, C tripping characteristic, 30 mA AC-type residual current, 6 kA breaking capacity per EN 60898 and IEC 60947-2, insulation voltage 440 V.

Does the 5SU9346-1CN10 require derating at higher ambient temperatures?

Yes. The 10 A rating holds at 30 °C; derate to 9.1 A at 40 °C, 8.7 A at 45 °C, 8.3 A at 50 °C, and 7.8 A at 55 °C. Size the load against the derated figure for the enclosure's internal temperature.

MPN
5SU9346-1CN10